ACCULINK 3350 E1 NTU
4-18
June 1996
3350-A2-GB20-10
3. From the Loopback screen, press the
key until
the RLB selection appears on the screen.
F1
Loopback:
Abort
LLB
PLB
F2
F3
4. Select RLB.
F1
Loopback:
PLB
DLB
RLB
F2
F3
Test Started appears on Line 2. If a Repeater
loopback is already in progress, the Already
Active message appears. If an invalid combination
of loopbacks is in progress, the error message
Invld Test Combo appears (see Table 4-9 for valid
loopback test combinations).
Aborting Loopbacks
The Abort Loopback command stops all loopback tests
or any selected loopback test currently active on the E1
NTU.
To abort one or more loopback tests,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
F1
Test:
Lpbk
Ptrns
Lamp
F2
F3
3. From the Loopback screen, select Abort.
F1
Loopback:
Abort
LLB
PLB
F2
F3
4. From the Loopback Abort screen, press the
desired Function key to abort All or one specific
loopback test. Use the scroll keys, if necessary.
F1
Loopback: Abort
All
LLB
PLB
F2
F3
When abort is complete, the message Command
Complete appears on the Abort screen.
NOTE
Be careful when selecting a
specific loopback test to abort. If
you mistakenly choose to abort a
loopback test that is not currently
running, a Command Complete
message will still display and the
loopback that is currently active
will still be running. You can use
the TStat branch of the menu to
view the test status to determine if
the abort was successful.