ACCULINK 3350 E1 NTU
3-12
June 1996
3350-A2-GB20-10
To select the COM port as the management link,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the
User selection appears on the screen.
5. Select User.
F1
Edit:
NET
Gen
User
F2
F3
6. Press F1 (Next) until the Com Use configuration
option appears.
7. Select SNMP to configure the COM port as the
management link to an external SNMP manager.
F1
Com Use:
Next
SNMP
ASCII
F2
F3
Setting the IP Address
The IP address is the address used by the SNMP
manager to access the device. For devices using PPP, the
IP address can be negotiated if the network device (e.g.,
router or SNMP manager) supports such negotiation. The
IP address is composed of four fields with three digits per
field (xxx.xxx.xxx.xxx).
The IP address is set for the COM port or the AUX
port (with LAN Adapter or daisy chain), depending on
which one has been chosen as the SNMP communications
link. The example below assumes that an IP address of
010.155.111.222 is being set for the COM port. You can
use the same principles to assign any value (between 000
and 255 for each digit field) to either port.
To assign an IP address to the COM port,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the
SNMP selection appears on the screen.
5. Select SNMP.
F1
Edit:
User
Alarm
SNMP
F2
F3