SP+ Series Programming Guide
51
BabyWare Options
Use worksheet 48 to record your settings for BabyWare options.
NOTE:
For increased communication security, you will be prompted to change the default panel ID and PC password.
IP and Software Configurations
Use the following section to configure IP and software requirements on your SP+ control panel.
IP Account Numbers
Use worksheet 49 to record the IP account numbers for network communication.
Software and PCS Connection Settings
Use worksheet 50 to record connection settings for BabyWare and PCS series.
IP Receiver Configurations
Use worksheets 51 to 53 (on page 52) to configure IP receivers. Table 44 provides a description of the IP/GPRS registration status.
Worksheet 48: BabyWare Options
Section Data
Description
[910]
___/___/___/___
Panel ID
[911]
___/___/___/___
PC password
[915]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
PC telephone number (landline communication only)
Worksheet 49: IP Account Numbers
Section Data
Description
[918]
___/___/___/___
IP account partition 1
[919]
___/___/___/___
IP account partition 2
Worksheet 50: Software and PCS Connection Settings
Section Data
Description
Default
[920]
__/__/__/__/__
Port
10000
[921]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
Access point name (APN), part 1 (e.g.,
internet.com
)
-
[922]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
Access point name (APN), part 2
-
[923]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
User name, part 1
-
[924]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
User name, part 2
-
[925]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
Password, part 1
-
[926]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
Password, part 2
-
[927]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
Installer software password (BabyWare)
admin
Table 44: IP/GPRS registration status
Key
Main Menu Trouble
Key
Sub-menu Trouble
1
IP/GPRS module registration status
1
OFF = Unregistered
1
Slow flash = Registering
1
ON = Registration OK
2
IP/GPRS module error
7
No IP/GPRS module
8
Ethernet cable unplugged; PCS no service
9
No IP address acquired by module/GPRS network trouble
3
IP/GPRS programming error
7
No IP address (not programmed)
8
No IP port (not programmed)
9
No IP account (not programmed)
10
No access point name (not programmed; GPRS only)
4
IP/GPRS registration error
7
Cannot connect
8
Invalid profile
9
Invalid format
10
Account already registered under another MAC address
Register module
-
When all troubles are cleared, press
ARM
to register module