Page 22
Configuring the PCS250
Enter the following command to view the SMS reporting settings
(VSMS):
1)
Send the VSMS command:
P[
PASSWORD
].VSMS.[
CALLBACK
PHONE
NUMBER
]
(e.g., Padmin.VSMS.5145552222)
2)
If the SMS reporting parameters are programmed properly,
the following SMS will be received:
[S
ITE
ID]
SMS#: [GSM
MODEM
TELEPHONE
# (5145551111)]
Password: [IPRS-7
PASSWORD
(123456)]
Status: [IPRS-7
REGISTRATION
STATUS
]
3)
If nothing is programmed or the programmed information
has been cleared, the following SMS will be received:
[
SITE
NAME
SMS
RECEIVER
NOT
PROGRAMMED
]
Enter the following command to clear the programmed SMS
parameters:
•
P[password].SMS.clear
SMS commands reference:
IMPORTANT:
Do not register the Backup IP receiver (SP-Series: [949],
EVO-Series: [2991]); doing so will delete the PCS250 SMS
configuration.
SMS
- Program the
receiver’s SMS
parameters
P[password].SMS.[GSM modem
telephone #].[IPRS-7 password]
VSMS
- View the SMS
reporting settings
P[password].VSMS.[callback phone
number]
Clearing the
programmed SMS
parameters
P[password].SMS.clear