Configuring the PCS250 Page 21
SMS Backup Reporting
The PCS250 GPRS/GSM Communicator Module supports SMS
backup reporting to an IPRS-7 (IP/GPRS PC Receiver Software)
when used in conjunction with a compatible Paradox control
panel.
•
SP5500/SP6000/SP7000 v4.76
•
EVO192 v2.65
•
SP4000/SP65 v4.94
This advanced feature assures continuous communication with
the protected premises. With the addition of a GSM/GPRS
modem, the IPRS-7 software will be able to receive alarm signals
through SMS text messages when GPRS communication is
disrupted. Should the GPRS channel fail to transmit from a
protected premise because of a power outage or internet failure,
a backup SMS will automatically be sent to the IPRS-7 (containing
the same CID information of the reportable event).
Configuring the PCS250 for SMS Backup Reporting
Enter the following command to program the receiver’s SMS
parameters:
1)
Send the SMS command:
P[
PASSWORD
].SMS.[GSM
MODEM
TELEPHONE
#].[IPRS-7
PASSWORD
]
(e.g., Padmin.SMS.5145551111.123456)
2)
Wait two minutes. The PCS250 will automatically register to
the IPRS-7 receiver. This will automatically program the
Backup IP receiver, IP address and port as follows:
IP address = 000.000.000.001
Port number = 00001
Backup IP receiver section reference:
Control Panel
IP
address
Port
Password
Register
IP/GPRS
module
SP Series
[943]
[944]
[947]
[949]
EVO Series
(IP Receiver #4)
[2990]
[2991]