Paradox PARAKEY Installer'S Manual Download Page 8

required data is entered, the keypad will emit a
confirmation beep and the Parakey will
automatically save and exit the section. If you make
a mistake, pressing [

CLEAR

] when entering data will

erase the current entry. Return to step 3 or press
[

CLEAR

] to exit Programming Mode.

• Sections [09] to [16]

RF Programming - Press the [

ENTER

] key and press

button 1 twice on the remote control to assign
remote control to corresponding user. The keypad
will emit a confirmation beep and the Parakey will
save and exit the section. Return to step 3 or press
[

CLEAR

] to exit Programming Mode.

• Sections [25] - [30]

Decimal Select - Each section represents one
feature and each key from [0] to [8] represents a
specific setting. Unlike feature select programming,
only one key can be selected. The selected key will
remain illuminated. Press the key representing the
desired setting and press [

ENTER

].

• Sections [17] - [24] & [31] - [35]

Feature Select - After entering the section, each key
from [1] to [8] represents a feature or option. The on/off
status of these keys determines the feature's setting.
Turn the keys on/off by pressing the appropriate key
until the desired options are set and press the [

ENTER

]

key. The keypad will emit a confirmation beep and the
Parakey will save and exit the section. Return to step
3 or press [

CLEAR

] to exit Programming Mode.

PROGRAMMING THE SYSTEM

Section [35] - Feature Select Programming: [1]
The Parakey can be set to accept 6-digit or 4-digit User
and Installer Access Codes. 
Key [1] OFF = 4-digit access codes.
Key [1] ON = 6-digit access codes (default).

This option must be set to the same access code
length as set in the control panel at address 088,
key [9].

Section [00] - Access Code Programming
The Installer Code provides you with access to program
all the functions & features of the Parakey System. The
Installer Code can be 4 or 6 digits in length (see section
4.1) with each digit being any value from 0 to 9. 

The Parakey system supports up to eight users, each with a
different remote control. As demonstrated in figure 5, the
three parameters listed below are specific to each user and
each user must be defined with all three of these parameters.

• User Access Code
• Remote Control Assignment
• User Remote Control Options 

4.3 User Parameters

4.2 Installer Code (Default: 757575)

4.1 Access Code Length

12

13

Summary of Contents for PARAKEY

Page 1: ...Remote Arming Module V1 10 318MHz 433MHz With KEELOQ high security code encryption Installer s Guide PARKEI 02 i i...

Page 2: ...2 5 Programmable Outputs PGMs 6 2 6 Hand Held Remote Control 7 2 7 System Reset 8 HOW TO PROGRAM 11 PROGRAMMING THE SYSTEM 13 4 1 Access Code Length 13 4 2 Installer Code 13 4 3 User Parameters 13 4 3...

Page 3: ...imple user friendly programming Supports 8 User Codes each linked to a unique RF Code 2 or 4 button remote control Encrypted RF codes for additional security Does not use DIP switch programming 4 prog...

Page 4: ...hen used in conjunction with any Paradox Esprit Series Control Panel the auxiliary terminals 12VDC of the control panel may power the Parakey Receiving Module as shown in figure 3 If using an external...

Page 5: ...age door when button 1 is pressed on the remote control Please refer to figure 1 and section 4 for more information There are two types of hand held PARAKEY remote controls There is a 2 button RF tran...

Page 6: ...vice versa To execute a system reset perform the following 1 Remove the power connections 12 GND from the receiver 2 Press and hold the PROG button and re connect the power connections to the receiver...

Page 7: ...illuminate If at any time you wait longer than 2 minutes between each key entry the Parakey will automatically exit the Programming Mode 3 1 2 Step 2 Key in Installer Code Press ENTER and key in the I...

Page 8: ...etting Turn the keys on off by pressing the appropriate key until the desired options are set and press the ENTER key The keypad will emit a confirmation beep and the Parakey will save and exit the se...

Page 9: ...ively figure 5 The User Access Code programmed in the Parakey must be the same as a User Access Code programmed in the Paradox Esprit Series Control Panel 4 3 2 Remote Control Assignment Sections 09 t...

Page 10: ...ressing the corresponding button will activate toggle any PGMs defined by the Button PGM Options section 4 7 Default all ON Key 4 OFF Disabled ON Button 1 PGM Enabled Key 5 OFF Disabled ON Button 2 PG...

Page 11: ...specified period of time At the end of this period the output will return to its normal state Each PGM output can be programmed with a separate output timer In the section corresponding to the desire...

Page 12: ...ot install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller ob...

Reviews: