The  PARAKEY is a wireless remote control system that
consists of a receiving module and up to eight 2 or 4-button
remote controls (transmitters). When used in conjunction
with any 

Paradox Esprit Series Control Panel, remote

controls can perform actions such as remote arming and
disarming, communicating panic alarms and/or activating
programmable outputs (PGMs). Each remote control is
assigned to a specific user and therefore, identifies the user
to the control panel when used. If desired, it can be used as
a stand-alone system where the remote controls will only
activate the on-board PGM outputs. When a button on the
remote control is pressed, it will transmit an RF signal.
When the PARAKEY receives this signal, it then processes
the request and performs the programmed action(s).

• Simple, user-friendly programming.
• Supports 8 User Codes, each linked to a unique RF

Code (2 or 4-button remote control).

• Encrypted RF codes for additional security. Does not

use DIP switch programming.

• 4 programmable outputs (PGMs).  
• Stand-alone operation (trigger PGMs only) or in

conjunction with a 

Paradox Esprit Series Control Panel

(arm/disarm, panic & PGM activation).

• Programming keypad connects directly to the Parakey

Receiving Module.

• Programmable Installer Code.
• Software reset.

1.2.1 Receiver:
Compatible Programming Keypads: (616 V4.2A & up)

(626 V4.1A & up)

DC input:

12VDC

PGM outputs:

4

PGM Output 1-3 Current Rating:

30mA max.

PGM Output 4 Current Rating:

5A relay

Max Transmission Range:

53.34m (175 ft.)

Operating Conditions:

0°C to 50°C

Operating Humidity:

85%

Operating Frequency:

318 or 433.92MHz

Sensitivity:

-110dbm

1.2.2 Remote Control:
Water Resistant
Battery:

Lithium 3V (CR2032)

Battery Life:

Apprx. 2 years

Power Transmission:

7mW

Current Consumption:

6mA (transmission)

1.2 Technical Specifications

1.1 Features

2

3

Summary of Contents for PARAKEY

Page 1: ...Remote Arming Module V1 10 318MHz 433MHz With KEELOQ high security code encryption Installer s Guide PARKEI 02 i i...

Page 2: ...2 5 Programmable Outputs PGMs 6 2 6 Hand Held Remote Control 7 2 7 System Reset 8 HOW TO PROGRAM 11 PROGRAMMING THE SYSTEM 13 4 1 Access Code Length 13 4 2 Installer Code 13 4 3 User Parameters 13 4 3...

Page 3: ...imple user friendly programming Supports 8 User Codes each linked to a unique RF Code 2 or 4 button remote control Encrypted RF codes for additional security Does not use DIP switch programming 4 prog...

Page 4: ...hen used in conjunction with any Paradox Esprit Series Control Panel the auxiliary terminals 12VDC of the control panel may power the Parakey Receiving Module as shown in figure 3 If using an external...

Page 5: ...age door when button 1 is pressed on the remote control Please refer to figure 1 and section 4 for more information There are two types of hand held PARAKEY remote controls There is a 2 button RF tran...

Page 6: ...vice versa To execute a system reset perform the following 1 Remove the power connections 12 GND from the receiver 2 Press and hold the PROG button and re connect the power connections to the receiver...

Page 7: ...illuminate If at any time you wait longer than 2 minutes between each key entry the Parakey will automatically exit the Programming Mode 3 1 2 Step 2 Key in Installer Code Press ENTER and key in the I...

Page 8: ...etting Turn the keys on off by pressing the appropriate key until the desired options are set and press the ENTER key The keypad will emit a confirmation beep and the Parakey will save and exit the se...

Page 9: ...ively figure 5 The User Access Code programmed in the Parakey must be the same as a User Access Code programmed in the Paradox Esprit Series Control Panel 4 3 2 Remote Control Assignment Sections 09 t...

Page 10: ...ressing the corresponding button will activate toggle any PGMs defined by the Button PGM Options section 4 7 Default all ON Key 4 OFF Disabled ON Button 1 PGM Enabled Key 5 OFF Disabled ON Button 2 PG...

Page 11: ...specified period of time At the end of this period the output will return to its normal state Each PGM output can be programmed with a separate output timer In the section corresponding to the desire...

Page 12: ...ot install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller ob...

Reviews: