background image

 

14

User Guide

Power Save Mode 

(MG32LRF only)

If there is power loss on the wireless keypad, the module’s display will shut off and go into power save mode after one minute. Press the 

[I

NFO

]

 key to activate the display. 

Trouble Display

Your alarm system continuously monitors several trouble conditions that can be reported directly to your monitoring station. When a 
trouble condition occurs, the [

TBL

] key will illuminate. We strongly suggest that you inform your monitoring station of the trouble and 

allow them to service your system.

The keypad can be programmed to emit a 

BEEP

 every 5 seconds whenever a new trouble condition has occurred. Press the 

[

TBL

]

 key to stop the 

“Trouble Beep”.

Trouble List

[1] Wireless Zone Low Battery

: The battery voltage in one or more wireless zones is getting low. 

[2] Power Trouble

: Five types of power trouble - 

[1]

 The control panel is experiencing low/no battery. 

[2]

 There is an AC failure on the 

control panel. 

[3]

 There is an auxiliary overload on the control panel. 

[4]

 A wireless keypad is experiencing AC failure. 

[5]

 A wireless 

keypad is experiencing battery failure.

[3] Bell Trouble

: There is a bell disconnect/overload on the control panel.

[4] Communication Trouble

: Your alarm system, if monitored, could not communicate with the monitoring station. 

[5] Tamper/Zone Wiring Failure

: A wiring problem is occurring on one or more zones.

[6] Module Tamper Trouble

: A module’s anti-tamper switch has been triggered.

[7] Fire Loop Trouble

: Indicates a wiring trouble on a fire zone.

[8] Timer Loss: 

Your alarm system’s clock must be reprogrammed. 

This is the only trouble that we recommend that you correct.

[9] Wireless Zone Supervision Loss

: One or more wireless zones are no longer communicating with the control panel.   

[10] Module Supervision Loss

: One or more modules are no longer communicating with the control panel.

[16] Keypad Fault 

(MG32LED/MG32LRF only): One or more keypads are no longer communicating with the control panel.

[

SLEEP

]

 

Keypad Fault 

(MG10LEDV/H only): One or more keypads are no longer communicating with the control panel.

How do I access the Trouble Display?

1

Press the 

[

TBL

key. The 

[

TBL

]

 key will flash and number(s) corresponding to the trouble(s) will illuminate (except 

MG32LCD)

2

Read the corresponding explanation of the trouble from the 

Trouble List 

below. If no repair instructions are given, call your 

monitoring station for repairs.

3 Press the 

[

CLEAR

]

 key to exit.

How do I reprogram the clock?

1 Press 

[8]

 for Timer Loss.

2

Enter the hour and minutes. If the hour is between 01 and 12, you will need to select 

[1]

 for 24Hr format, 

[2]

 for AM, and 

[3]

 for PM setting. If the hour is above 12, the system will automatically select the 24Hr format. 

3 Enter the year (4 digits). 
4 Enter the month (2 digits). 
5 Enter the day (2 digits). You have now set the Time & Date. Press 

[

CLEAR

]

 to exit.

Summary of Contents for Magelan MG5000

Page 1: ...ser Guide We hope this product performs to your complete satisfaction Should you have any questions or comments please visit www paradox com and send us your comments MG5000 MG5050 SP5500 SP6000 SP700...

Page 2: ...15 _____________________________________ ________ N N N N N Duress Y N N N 016 _____________________________________ ________ N N N N N Duress Y N N N 017 _____________________________________ _______...

Page 3: ...Goes to next available user Notes By default User 1 has access to both partitions User 2 has access to partition 1 only and User 3 has access to partition 2 only These settings cannot be modified Ste...

Page 4: ...rt to the monitoring station Step Action Details 1 MASTER CODE The key will flash PARTITION MASTER CODE may also be used 2 BYP 3 1 Auto arm partition 1 2 Auto arm partition 2 4 HH MM Enter time 24Hr c...

Page 5: ...ular Arming 9 Sleep Arming 9 Stay Arming 9 One Touch Arming 10 Auto Arming 10 Disarming Deactivating an Alarm 11 Manual Bypass Programming 11 System Features 12 Display Mode 12 Alarm Display 12 Fire A...

Page 6: ...ode the keypad produces an intermittent beep tone BEEP BEEP BEEP BEEP Rejection Beep When the system reverts to its previous status or when an operation is incorrectly entered on the keypad it will em...

Page 7: ...hold to set chime zones see page 13 TBL Trouble display ON Trouble s occurring MEM Alarm memory display ON Alarm s occurred BYP Bypass programming ON Zone s bypassed Zone Display The numbers 1 to 32 c...

Page 8: ...and many of your system s features can be assigned to either Partition 1 Partition 2 or both partitions If the system is not partitioned all zones user codes and features will be recognized as belong...

Page 9: ...that the exit path is assigned to This will start an exit delay period for all zones in the exit path After you have left the property all exit path zones will rearm The system is now in Full mode Ent...

Page 10: ...mmediately transmit a silent alert Duress Code to the monitoring station Must be enabled by your installer Programming Access Codes Your system can be programmed to use either 4 or 6 digit access code...

Page 11: ...ee Auto Arming on page 10 or One Touch arming see One Touch Arming on page 10 Stay Arming This method allows you to roam freely within the premises while the perimeter is fully armed Stay zones are zo...

Page 12: ...Mode See Manual Bypass Programming on page 11 Fast Exit When the system is already Stay or Sleep armed This feature will allow you to exit already armed premises and keep the system armed Press and ho...

Page 13: ...ey will illuminate If One Touch Bypass Programming is enabled press the BYP key for three seconds to enter Bypass Programming Press ENTER after step 2 to bypass all open zones Press CLEAR twice to exi...

Page 14: ...king fires often result from unattended cooking and human error rather than mechanical failure of stoves or ovens Careless smoking is the leading cause of fire deaths Smoke detectors and smolder resis...

Page 15: ...e PGM Press and hold CLEAR ENTER or for three seconds to perform a smoke reset These features must be set by your installer How do I chime zones MG32LED MG32LRF 32 zone hardwired wireless LED keypad m...

Page 16: ...Failure A wiring problem is occurring on one or more zones 6 Module Tamper Trouble A module s anti tamper switch has been triggered 7 Fire Loop Trouble Indicates a wiring trouble on a fire zone 8 Time...

Page 17: ...ad software Cancel Communication MEM 9 Cancels all communication with the WinLoad software if it has been initiated Testing Maintenance With the system disarmed and the OFF light illuminated activate...

Page 18: ...________________ ______ N N N N N N Fire Zone Y N N N Delayed Y N N N 16 ___________________________________ ______ N N N N N N Fire Zone Y N N N Delayed Y N N N 17 ___________________________________...

Page 19: ...cerns would include without limitation Internet connection failures which may be more frequent than regular telephone line outages We therefore strongly recommend that you discuss these and other limi...

Page 20: ...paradox com Printed in Canada 07 2007 MGSP EU08...

Reviews: