background image

 Magellan / Spectra SP

11

No Movement Auto Arming

The alarm system can be programmed to arm the system and/or send a report if no zone activity occurs for a pre-programmed amount of 
time. This is a particularly useful feature when supervising an individual with chronic health problems or a person who lives alone. The 
system will bypass any open zones. 

Disarming & Deactivating an Alarm 

To disarm an armed system or an alarm, press 

[

OFF

]

 and enter your 

[

ACCESS

 

CODE

]

. An entry point, like the front door, will be 

programmed with one of two Entry Delay Timers. When an entry point is opened, the keypad will beep until you disarm the system. Your 
alarm system will not generate an alarm until this timer elapses. Any user can disarm a partition they have been assigned to, except 
users assigned with the Arm Only Option or PGM Only Option.To disarm alarms generated by a

 

Delayed Fire Zone, refer to 

Fire Alarms 

on page 12.

Manual Bypass Programming

Manual Bypass Programming allows you to program the alarm system to ignore (deactivate) specified zones the next time the system is 
armed. For example, you may wish to bypass certain zones when workers are renovating part of your establishment. Once the system is 
disarmed, the bypass entries are erased. Manual Bypass Programming can also be activated by using One-Touch Bypass Programming 
(see the note below). To remove the Bypass feature from a zone, in step 3 enter the zone number again or press 

[

CLEAR

]

 to erase all 

current entries. When zones are bypassed, the 

[

BYP

]

 key will illuminate.

If One-Touch Bypass Programming is enabled, press the 

[

BYP

]

 key for three seconds to enter Bypass Programming.

Press 

[

ENTER

]

 after step 2 to bypass all open zones. Press

 [

CLEAR

twice to exit without saving. Press

 [

CLEAR

+

 [

ENTER

to delete bypassed zones.

Bypass Recall Feature

After disarming the system, the bypass entries are erased. The Bypass Recall feature reinstates the previous bypass entries saved in 
memory. This eliminates the need to manually re-program the bypass entries every time you arm the system.

How do I temporarily disable the Auto-Arm Timer?

1 Press the 

[ ]

 key.

2 Enter 

[

MASTER

 

CODE

]

.

3 Press the 

[

BYP

]

 key. The 

[

BYP

]

 key will flash to indicate you are in the System Options menu.

4 Press key 

[1]

 to set partition 1, or press key 

[2]

 to set partition 2. 

5 Press and hold 

[

SLEEP

]

 to temporarily disable the Auto-Arm Timer.

How do I disarm the system?

For a Stay or Sleep armed system, go to step 2.

1 Enter through a designated entry point (e.g. front door). 
2 Press 

[

OFF

]

 + enter 

[

ACCESS

 

CODE

]

.

3

If you have access to both partitions (see 

Partitioning 

on page 6): Press the key corresponding to the desired partition (

[1]

 or 

[2]

)

.

 For both partitions, press the other key after the confirmation beep. 

How do I deactivate an alarm?

Press 

[

OFF

]

 + enter 

[

ACCESS

 

CODE

]

.

How do I bypass zones?

1 Press the 

[

BYP

key. 

2 Enter 

[

ACCESS

 

CODE

]

 

(see the note below). 

The 

[

BYP

key will flash.

3

Illuminate the number(s) corresponding to the zone(s) you want to bypass by entering the two-digit zone number (e.g. 
zone 3 = 03). Solid on = Zone open, Flash = Zone bypass, Off = Zone closed, not bypassed.

4 Press the 

[

ENTER

]

 key to save and exit.

How do I recall bypass entries?

1 Press the 

[

BYP

key.

2 Enter your 

[

ACCESS

 

CODE

]

.

3 Press the 

[

BYP

]

 key. 

4 Press the 

[

ENTER

]

 key.

Summary of Contents for Magelan MG5000

Page 1: ...ser Guide We hope this product performs to your complete satisfaction Should you have any questions or comments please visit www paradox com and send us your comments MG5000 MG5050 SP5500 SP6000 SP700...

Page 2: ...15 _____________________________________ ________ N N N N N Duress Y N N N 016 _____________________________________ ________ N N N N N Duress Y N N N 017 _____________________________________ _______...

Page 3: ...Goes to next available user Notes By default User 1 has access to both partitions User 2 has access to partition 1 only and User 3 has access to partition 2 only These settings cannot be modified Ste...

Page 4: ...rt to the monitoring station Step Action Details 1 MASTER CODE The key will flash PARTITION MASTER CODE may also be used 2 BYP 3 1 Auto arm partition 1 2 Auto arm partition 2 4 HH MM Enter time 24Hr c...

Page 5: ...ular Arming 9 Sleep Arming 9 Stay Arming 9 One Touch Arming 10 Auto Arming 10 Disarming Deactivating an Alarm 11 Manual Bypass Programming 11 System Features 12 Display Mode 12 Alarm Display 12 Fire A...

Page 6: ...ode the keypad produces an intermittent beep tone BEEP BEEP BEEP BEEP Rejection Beep When the system reverts to its previous status or when an operation is incorrectly entered on the keypad it will em...

Page 7: ...hold to set chime zones see page 13 TBL Trouble display ON Trouble s occurring MEM Alarm memory display ON Alarm s occurred BYP Bypass programming ON Zone s bypassed Zone Display The numbers 1 to 32 c...

Page 8: ...and many of your system s features can be assigned to either Partition 1 Partition 2 or both partitions If the system is not partitioned all zones user codes and features will be recognized as belong...

Page 9: ...that the exit path is assigned to This will start an exit delay period for all zones in the exit path After you have left the property all exit path zones will rearm The system is now in Full mode Ent...

Page 10: ...mmediately transmit a silent alert Duress Code to the monitoring station Must be enabled by your installer Programming Access Codes Your system can be programmed to use either 4 or 6 digit access code...

Page 11: ...ee Auto Arming on page 10 or One Touch arming see One Touch Arming on page 10 Stay Arming This method allows you to roam freely within the premises while the perimeter is fully armed Stay zones are zo...

Page 12: ...Mode See Manual Bypass Programming on page 11 Fast Exit When the system is already Stay or Sleep armed This feature will allow you to exit already armed premises and keep the system armed Press and ho...

Page 13: ...ey will illuminate If One Touch Bypass Programming is enabled press the BYP key for three seconds to enter Bypass Programming Press ENTER after step 2 to bypass all open zones Press CLEAR twice to exi...

Page 14: ...king fires often result from unattended cooking and human error rather than mechanical failure of stoves or ovens Careless smoking is the leading cause of fire deaths Smoke detectors and smolder resis...

Page 15: ...e PGM Press and hold CLEAR ENTER or for three seconds to perform a smoke reset These features must be set by your installer How do I chime zones MG32LED MG32LRF 32 zone hardwired wireless LED keypad m...

Page 16: ...Failure A wiring problem is occurring on one or more zones 6 Module Tamper Trouble A module s anti tamper switch has been triggered 7 Fire Loop Trouble Indicates a wiring trouble on a fire zone 8 Time...

Page 17: ...ad software Cancel Communication MEM 9 Cancels all communication with the WinLoad software if it has been initiated Testing Maintenance With the system disarmed and the OFF light illuminated activate...

Page 18: ...________________ ______ N N N N N N Fire Zone Y N N N Delayed Y N N N 16 ___________________________________ ______ N N N N N N Fire Zone Y N N N Delayed Y N N N 17 ___________________________________...

Page 19: ...cerns would include without limitation Internet connection failures which may be more frequent than regular telephone line outages We therefore strongly recommend that you discuss these and other limi...

Page 20: ...paradox com Printed in Canada 07 2007 MGSP EU08...

Reviews: