IPR512: IP Monitoring Receiver
8 of 8
Quick Start
Installer Instructions
Setup Control Panel and Register Paradox Reporting Module
The installer must program the following settings in the control panel (steps 1 to 4 below) and then register the
communication module with the IPR512 (step 5 below).
STEP
MG/SP/E55/E65
EVO
1.
Ensure that the panel’s report
code format is set to either
Ademco Contact ID (default) or
SIA. The # represents the tele-
phone number and the IP
Receiver number
[810]
__ / __ (IP#1 / IP#2)
4 = Contact ID 5 = SIA
[3070]
__ / __ / __ / __ (IP#1 / IP#2 /IP#3 / IP#4)
5 = Contact ID 6 = SIA
2.
Enter the IP reporting account
numbers (one for each
partition). These account
numbers are independent of
the landline dialer account
numbers, but you can program
the same value.
[918]
= Partition 1
[919]
= Partition 2
[2976]
= Partition 1
[2980]
= Partition 5
[2977]
= Partition 2
[2981]
= Partition 6
[2978]
= Partition 3
[2982]
= Partition 7
[2979]
= Partition 4
[2983]
= Partition 8
3.
- Set the IP Line Monitoring
options ([5] and [6]).
- Set the Landline Dialer
Reporting option ([7]).
- Enable IP reporting ([8]).
[806] Bold = default setting [2975] Bold = default setting
4.
Enter the IP address(es), IP
port(s), receiver password(s),
and security profile(s) of the
monitoring station’s Paradox
IPR512 IP Monitoring
Receiver(s). This information
is provided by the monitoring
station.
* Port, Password, and Profile are set in the same
section as the Address.
5.
Register the Paradox reporting
module with the receiver by
entering the appropriate
section and pressing
[
ARM
]
.
The registration status is
displayed as well as any
registration errors.
PARADOX.COM
IPR512-EQ01 10/2008
© 2008 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142,
6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international
patents may also apply.
For the latest information on products approvals, such as UL and CE, please visit www.paradox.com. For complete warranty information on this product
please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and
conditions.
[5] [6] IP Line Monitoring Options
off off Disabled
off on When disarmed: Trouble only
When armed: Trouble only
on off When disarmed: Trouble only
When armed: Audible alarm
on on Silent alarm becomes audible
alarm
[7]
Landline Dialer Reporting
OFF = As backup to IP reporting
ON = In addition to IP reporting
[8] IP Reporting
OFF = Disabled
ON = Enabled
[5] [6] IP Line Monitoring Options
off off Disabled
off on When disarmed: Trouble only
When armed: Audible alarm
on off When disarmed: Trouble only
When armed: Trouble only
on on Silent alarm becomes audible
alarm
[7]
Landline Dialer Reporting
OFF = As backup to IP reporting
ON = In addition to IP reporting
[8] IP Reporting
OFF = Disabled
ON = Enabled
IP Receiver #
#1
#2 Backup
IP Address WAN1
[929] [936]
[943]
IP Port WAN1
[930] [937]
[944]
IP Address WAN2
[931] [938]
[945]
IP Port WAN2
[932] [939]
[946]
IP Password
[933] [940]
[947]
IP Profile
[934] [941]
[948]
IP Receiver #
#1
#2
#3
#4
IP Address WAN1
[2984] [2986] [2988] [2990]
IP Port WAN1
*
*
*
*
IP Address WAN2
*
*
*
*
IP Port WAN2
*
*
*
*
IP Password
*
*
*
*
IP Profile
*
*
*
*
IP Receiver #
#1
#2 Backup
Register/Status
[935] [942]
[949]
IP Receiver #
#1
#2
#3
#4
IP Address
[2985]
[2987] [2989] [2991]