32 Reference & Installation Manual
6.5.2 D
OOR
F
ORCED
O
PEN
F
EEDBACK
S
ECTION
[004]: O
PTIONS
[7]
AND
[8]
The Access Alarm can be either audible or silent and will either
beep as long as the Access Alarm is occurring or follow the
Beep Timer in section [013]. The sound of the Door Forced
Open Alarm resembles the rapid beep generated during the
last ten seconds of the Exit Delay.
Option [7] OFF= Door Forced Open Alarm is silent.
Option [7] ON = Door Forced Open Alarm is audible (default).
If option [7] is enabled:
Option [8] OFF= will beep as long as Door Forced Open Alarm
is occurring (default).
Option [8] ON = Door Forced Open Alarm follows Beep Timer.
(section [013]).
6.5.3 B
EEP
T
IMER
F
OR
D
OOR
F
ORCED
O
PEN
A
LARM
S
ECTION
[013]
This Beep Timer determines the amount of time the Door Forced
Open Alarm (see section 6.5.2 above) will beep. Enter any value
between 001 and 255 to determine the number of seconds the
Door Forced Open Alarm will beep. Default = 5 seconds.
6.6 ACCESS CONTROL PIN ENTRY OPTION
S
ECTION
[006]: O
PTION
[4]
If the Card and Code Access option is enabled in the DigiplexNE
control panel (refer to the Access Control section in the DigiplexNE
Reference & Installation Manual), the Access Control PIN Entry
option determines whether the PIN is entered on the Access Control
LCD keypad or on a PosiPIN Proximity Reader (CR-R885-BL). If the
reader being used is a PosiPIN and section [006] option [4] is ON,
the user must present their access control card to the reader and
Summary of Contents for DGP2-641
Page 1: ...LCD Access Control LCD Keypad V1 0 DGP2 641 DGP2 641AC Reference and Installation Manual...
Page 10: ...8 Reference Installation Manual Figure 1 Connecting the Keypad and Keypad Zone...
Page 12: ...10 Reference Installation Manual Figure 4 Access Control Connections DGP2 641AC...
Page 13: ...Digiplex DigiplexNE LCD Keypad 11n Figure 5 Connecting a Shielded Routing Cable...
Page 38: ...36 Reference Installation Manual Table 2 Special Characters Catalog...
Page 43: ......