Digiplex/DigiplexNE LCD Keypad 21
n
5.3 PGM BASE TIME
S
ECTION
[006]: O
PTION
[3]
If the keypad's on-board PGM is set in PGM Timed Mode (see
section 5.2 on page 20) you must define whether the value
programmed in section [008] is in minutes or seconds.
Option [3] OFF= PGM Base Time is 1 second (default).
Option [3] ON = PGM Base Time is 1 minute.
5.4 PGM OVERRIDE
S
ECTION
[006]: O
PTION
[4]
When the PGM override is enabled, the keypad's on-board PGM will
ignore PGM Activation Events (section 5.6, page 22), PGM
Deactivation Events (section 5.7, page 22), and PGM Timers (section
5.5, page 21). It will remain in its normal state until the PGM Override
is disabled. This option may be used to test the PGM connections.
Option [4] OFF= PGM Override disabled (default).
Option [4] ON = PGM Override enabled.
5.5 PGM TIMER
S
ECTION
[008]
If the keypad's on-board PGM is in PGM Timed Mode, the value
programmed in section [008] represents how long the PGM will
remain in its opposite state (see section 5.1 on page 20) after being
activated. To program the timer, enter a 3-digit decimal value (000 to
255) in section [008]. The 3-digit value will be multiplied by the PGM
Base Time of 1 second or 1 minute (see section 5.3 above). Default:
5 seconds.
Summary of Contents for DGP2-641
Page 1: ...LCD Access Control LCD Keypad V1 0 DGP2 641 DGP2 641AC Reference and Installation Manual...
Page 10: ...8 Reference Installation Manual Figure 1 Connecting the Keypad and Keypad Zone...
Page 12: ...10 Reference Installation Manual Figure 4 Access Control Connections DGP2 641AC...
Page 13: ...Digiplex DigiplexNE LCD Keypad 11n Figure 5 Connecting a Shielded Routing Cable...
Page 38: ...36 Reference Installation Manual Table 2 Special Characters Catalog...
Page 43: ......