Proximity Reader 7
CARD/CODE OPTIONS
Section [001] - Default: [3]
The reader can also function as a keypad.
KEYPAD COMMUNICATION FORMAT
Section [002] - Default: [1]
The reader must use the same keypad
communication format as the controller.
5. To program another section, repeat steps 3
and 4. To exit programming mode, press and
hold the [
CLEAR
] key for 4 sec.
The reader emits a rejection beep and the
green LED extinguishes.
Enter Description
[0]
Keypad and reader disabled.
For programming only.
[1]
Reader only enabled. A user must
present a valid card to the reader for
Access Granted.
[2]
Keypad only enabled. A user must enter
a valid code on the keypad for Access
Granted.
[3]
Keypad and reader enabled. A user
must present a valid card and enter a
valid code for Access Granted.
Enter Description
[0]
8-bit Wiegand (Motorola ARK).
[1]
26-bit Wiegand (also see section
[006]).
[2]
37-bit Wiegand