10 Installation Manual
26-BIT WIEGAND CARD FAMILY CODE
SETTING
Section [006] - Default: [000]
When the keypad is enabled, the card’s family code
must be programmed in order for the keypad to
recognize the user’s PIN. When a user enters a PIN
on the keypad, the reader will automatically add the
family code programmed in section [006] to the
beginning of the PIN before transmitting the data to
the controller. Therefore, also ensure that all cards
to be used with the reader contain the same family
code.
This feature only applies when the
communication format programmed in
Section [002] is set for Option [1]: 26-bit
Wiegand.
READER’S INTERFACE
Section [007] - Default: [0]
The reader must be programmed to use the same
communication format as the controller.
Enter Description
[0]
Keypad Lockout disabled.
[1]
Keypad Lockout enabled.
Enter
Description
[0] to [255] Cards’ Family Code.
Enter Description
[0]
26-bit Wiegand.
[1]
37-bit Wiegand.