Proximity Reader 11
CHECK-IN SUPERVISION
Section [008] - Default: [0]
This feature only applies when the
communication format programmed in
Section [002] is set for Option [1]: 26-bit
Wiegand or Option [2]: 37-bit Wiegand.
When no actions are performed on the reader for a
period of time, it will communicate its status to the
controller every 30 seconds by sending a code to
confirm its presence (26-bit Wiegand = 255:65535;
37-bit Wiegand = 65535:65535). If the reader does
not communicate its status every 30 seconds, the
controller can be programmed to generate an
alarm.
BUZZER SETTING
Section [101] - Default: [3]
The number of beep tones emitted as a response to
a card being presented to the reader can be
adjusted from 0 (disabled) to 7 (7 rapid beep
tones).
Enter
Description
[0]
Check-in Supervision disabled.
[1]
Check-in Supervision enabled.
Enter
Description
[0] to [7]
Number of beep tones per
response.