24 User’s Guide
Arming
(see section 4.3).
Exit and Force Arm:
Press and hold the
[
FORCE
]
button for 3
seconds (see
Note2
) to
start the
Exit Delay
(see section 4.1).
When the
Exit Delay
elapses, the system will switch to
Force
Arming
(see section 4.5).
4.7.4 One-Touch Force Arming
Press and hold the
[
FORCE
]
button for 3 seconds (see
Note2
) to
bypass any open
Force Zones
. For details on
Force Arming
,
refer to section 4.5.
4.7.5 One-Touch Bypass Programming
Press and hold the
[
BYP
]
button for 3 seconds (see
Note2
) to
access
Bypass Programming Mode
(see section 4.6).
4.8 K
EYSWITCH
A
RMING
A keyswitch can be used to arm and disarm the system. A
keyswitch is assigned to and programmed to
Stay Arm
(see section 4.4) or
Regular Arm
(see section 4.3) a
specific partition. A keyswitch can function as a Maintained
or Momentary keyswitch.
To arm the system using a Maintained Keyswitch, set the
keyswitch to the “on” position. To disarm the system set the
keyswitch to the “off” position.
To arm the system using a Momentary Keyswitch, set the
keyswitch to the “on” position then turn it back to the “off”
position. Repeating this sequence will disarm the system.
1686EU04.fm Page 24 Tuesday, August 13, 2002 10:01 AM