22
•
Single Side Burner Assembly
GS-SB1 Single Side Burner Operator Manual
Liquid propane gas is not natural gas. The use of NG in an LP
configured burner, or LP in an NG configured burner, is extremely
dangerous and voids your warranty.
Operation without a proper gas regulator will void all burner unit warranties.
Burner units operated with NG must be connected to the NG supply with NG flexline and the supplied NG
regulator. The NG valve is pre-set at the factory for proper operation. Contact your gas supply dealer and
use a licensed contractor or installer if you desire to convert your burner unit to LP gas supply.
Burner units operated with LP gas require an LP regulator set to 11.0" water column pressure. The self-
contained LP system burner unit is designed to be used with a standard 20 lb., 12 1/4" diameter, 18" high
cylinder with right-handed connection threads; this is the maximum size LP tank to be used. The cylinder
must be marked in accordance with:
•
U.S. Department of Transportation CFR49 Part 173 Specifications for LP Gas Cylinders
•
National Standards of Canada CSA-B339 Cylinders, Spheres and Tubes for the Transportation of
Dangerous Goods
The propane tank must be fitted with an Overfill Prevention Device (OPD). Do not twist the gas supply hose.
Connection
Natural Gas
A licensed plumber must install the required plumbing to supply your
NG burner unit.
The burner unit must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures equal to or less than
0.5 psi (3.5 kPa).
The burner unit must be isolated from the gas supply piping system
during any pressure testing of that system at test pressure in excess
of 0.5 psi (3.5 kPa).
Do not use any tape, pipe dope, or threading compound on any flare
fitting. Doing so may cause a clog in the regulator and prevent your
burner unit from safe and proper operation
To connect the burner unit to a natural gas source:
1.
Ensure all burner unit control valves are in the OFF position