68
208143 REV -
Operations Manual, HPA3, Mini Compact Outdoor SSPA
Data
Address
# Bytes
Description
Limits and Byte Values
23
1
Forward RF Fault Handling
Minor Fault = 255
Major Fault = 0
24
1
Forward RF Fault Handling
0-80 dBm. Value used as Low, Window center point, or High
Threshold, depending on Forward RF Fault status setting
25 1
Reserve
Reserve
26
1
Reserve
Reserve
27 1
Reserve
Reserve
28
1
Reserve
Reserve
29
1
IP Address Byte 1 (MSB)
Default IP Address = 192.168.0.9
30
1
IP Address Byte 2
Default IP Address = 192.168.0.9
31
1
IP Address Byte 3
Default IP Address = 192.168.0.9
32
1
IP Address Byte 4
Default IP Address = 192.168.0.9
33
1
IP Gateway Byte 1 (MSB)
Default Gateway = 192.168.0.1
34
1
IP Gateway Byte 2
Default Gateway = 192.168.0.1
35
1
IP Gateway Byte 3
Default Gateway = 192.168.0.1
36
1
IP Gateway Byte 4
Default Gateway = 192.168.0.1
37
1
Subnet Mask Byte 1 (MSB)
Default Subnet Mask = 255.255.255.0
38
1
Subnet Mask Byte 2)
Default Subnet Mask = 255.255.255.0
39
1
Subnet Mask Byte 3
Default Subnet Mask = 255.255.255.0
40
1
Subnet Mask Byte 4
Default Subnet Mask = 255.255.255.0
41
1
Receive IP Port Byte 1 (MSB)
Default Receive IP Port = 1007
42
1
Receive IP Port Byte 2
Default Receive IP Port = 1007
43
1
IP Lock Address Byte 1 (MSB)
Default IP Lock Address = 255.255.255.255 (Disabled)
44
1
IP Lock Address Byte 2
Default IP Lock Address = 255.255.255.255 (Disabled)
45
1
IP Lock Address Byte 3
Default IP Lock Address = 255.255.255.255 (Disabled)
46
1
IP Lock Address Byte 4
Default IP Lock Address = 255.255.255.255 (Disabled)
Table 8-7: System Settings Data Values (continued)
Data
Address
# Bytes
Description
Limits and valid values
1 2
Low Current Fault Threshold
(Power Supply 2 Current)
Minimum value = 0
Maximum value = 1023
2
2
Spare Fault Window
Lower Limit
Minimum value = 0
Maximum value = 1023
3 2
Spare Fault Window
Upper Limit
Minimum value = 0
Maximum value = 1023
4
2
Low Current Fault Threshold
(Power Supply 1 Current)
Minimum value = 0
Maximum value = 1023
5 2
Low Regulator Voltage Threshold
(Power Supply 2 Voltage)
Minimum value = 0
Maximum value = 1023
6
2
Low Regulator Voltage Threshold
(Power Supply 1 Voltage)
Minimum value = 0
Maximum value = 1023
Table 8-8: System Threshold Data Values