P300H
P300 Modem Installation and Operating Handbook
Page 69
Carrier: [?] 1=Off 2=On
3=Muted after pwr brk 4=Intfc RTS Controlled
Change, Tx, Modulator, Carrier Menu
Set Tx Power [-15.3dBm]
enter value ??.? (YES), or
to change
Change, Tx, Modulator, Power Menu
6.6.14 Change, Tx, Modulator, CARRIER Menu
The state of the Transmit Carrier is selected as follows:
OFF
The carrier is off.
ON
The carrier will remain on, and after a power break it will automatically return to
on.
POWER BREAK
MUTE
The carrier is switched on BUT after a power cut the carrier will be switched off
and a deferred alarm generated until either from the front panel or remotely the
unit is instructed to return the carrier to the on state.
RTS
CONTROLLED
The carrier will be dynamically controlled by the
`Sig Valid In`
, the RTS line on a
V.35 DCE interface (see interface card details in appendix A for line names for
other interfaces). No alarm is raised when the Tx carrier is muted by the RTS line
going to the `off` state unless the RTS line itself is set to raise an alarm if it goes
to the off state (
Change, Terr-Intfc, Control Lines
).
The operator is warned if the carrier is set to
POWER BREAK MUTE
when
SETUP-CHECK
is requested.
6.6.15 Change, Tx, Modulator, POWER LEVEL Menu
This menu allows control of the Transmit output power. This may be varied from 0dBm to -25dBm in 0.1dB
steps, either by direct entry of the required power or by using the up/down keys to adjust the current value
up or down in 0.1dB steps. Pressing the Up/Down keys rapidly causes the level to change in 0.5dB
increments. If AUPC is active (refer to AUPC in section 8.11.1 on page 143) then the delta power added
by the AUPC is also displayed on the top line.