P300H
P300 Modem Installation and Operating Handbook
Page 108
Distant Eb/No:9.7dB
Target:10.±0.5dB Delta power:+1.5dB
Monitor, AUPC Menu
Limits: +3.5 -1.0dB Slew:10dB/min
Comms lost action:Nominal
Monitor, AUPC Limits Menu
6.12.5 Monitor, AUPC Menu
This screen is only available when the AUPC feature is set to `Maintain Eb/No` or `Self Monitor` (refer to
AUPC in section 8.11.1 on page 143) when the AUPC is controlling the Tx power. The first line displays
either `Distant Eb/No` or `Self monitor` respectively, the lower line shows the target Eb/No along with its
tolerance window, and the current AUPC delta power. If the delta power reaches the preset limit either up
or down, then it is prefixed with either a
e
or
f
arrow indicating that the power limit has been reached.
The down arrow indicates that a subsequent screen (shown below) shows the limits the AUPC has been
constrained to work under:
Most of this is self explanatory except for the slew rate limit which limits the rate of change of Tx power (it
moves on 0.1dB steps at the appropriate rate to match the given slew rate). A slew rate limit of zero
however indicates `no limit`, and step changes in power will be made on the Tx output.