Page 1: ...User s Manual PRO LCD Series UPS Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000407 R2 ...

Page 2: ... Other trademarks are property of their respective owners 1 Introduction 2 2 Controls and Indicators 6 3 Installation 8 4 Operation 11 5 Troubleshooting 14 6 Replacing the Battery 15 7 Obtaining Service 19 8 Specifications 20 9 Limited Product Warranty 22 A1 Declaration of Conformity 23 English ...

Page 3: ...ING This Uninterruptible Power Supply contains potentially hazardous voltages Do not attempt to disassemble the UPS beyond the battery replacement procedure This UPS contains no user ser viceable parts Repairs and Battery replacement must be performed by QUALIFIED SERVICE PERSONNEL ONLY CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit ove...

Page 4: ...nt has been tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Sub part J of Part 15 of FCC Rules and the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference of the Canadian Depart ment of Communications These limits are designed to provide reasonable protection against such interference i...

Page 5: ... Displays the amount of Battery Capacity available in the AC and Battery mode 3 Load Capacity Bar Graph Displays the amount of load connected to the UPS in the AC and Battery mode 4 AC normal and Boost Buck mode Icon Illuminates when the UPS is in the AC normal mode and flashs when the UPS is in the Boost or the Buck mode 5 On Battery Icon Illuminates when the UPS is operating in the Battery mode ...

Page 6: ...er or excessive humidity or where the UPS is exposed to direct sunlight Select a location which will provide good air circulation for the UPS at all times Route power cords so they cannot be walked on or damaged Typi cal battery life is 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges have a negative impact on bat...

Page 7: ...s whenever the UPS is connected to anAC source and there is an acceptableAC voltage present 90 150VAC It is recommended that the UPS s batteries be charged for a minimum of 4 hours before use The UPS may be used immediately however the On Battery runtime may be less than normally expected Typical battery life is 3 to 5 years Environmental factors do affect battery life High temperatures poor utili...

Page 8: ...nger than the start up or user invoked test This every two week test will run for approximately fifteen seconds to measure the battery s capability to support the output load The start up and user invoked test will run for approximately ten seconds If the UPS fails one of these tests one of the icons or the information displayed on the LCD will remain illuminated indicating the type of problem NOT...

Page 9: ...efore attempting to service the batteries Typical battery life is 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges have a negative impact on battery life English Possible Cause Symptom What To Do Press hold and then release the On Off button to start UPS On Off Test button not pressed UPS will not turn on Reset ci...

Page 10: ...with the UPS on the load will not be backed up To hot swap the batteries start with step number 6 1 Turn off the equipment that is plugged into the output of the UPS 2 Turn off the UPS 3 Unplug the UPS s AC power cord from the AC wall outlet 4 Unplug the equipment from the output receptacles of the UPS 5 Unplug the computer interface cable from the rear panel of the UPS 6 Remove the front panel re...

Page 11: ...chnician about obtaining a new set It is important to pack the UPS properly in order to avoid damage in transit Never use Styrofoam beads for a packing material A Include a letter with your name address day time phone number RMA number a copy of your original sales receipt and a brief description of the problem 5 Mark the RMA on the outside of all packages The factory cannot accept any package wit...

Page 12: ...ating Temperature 0 to 35 degrees C 32 to 95 degrees F at Operating Elevation 1501 to 3 000m 0 to 10 000 ft 17 6 lbs 8 0 Kgs 19 8 lbs 9 0 Kgs 5 17 7 21 English 120VAC 1100VA 770W Protection Waveform Type Over Current Short Circuit Protected and Latching Shutdown Simulated Sine Wave Step Wave Frequency 50 60Hz 0 5Hz unless synchronized to utility Nominal Voltage Maximum Power Capacity 6 ms Typical ...

Page 13: ...ays of purchase The warranty shall be void if a the equipment is damaged by the customer is improperly used is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications b the equipment is repaired or modified by anyone other than Para Systems or Para Systems approved personnel or c has been used in a manner contrary to the product s User s Man...

Page 14: ...25 24 Notes Notes English English ...