background image

 

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: 

[email protected]

Model #: SU1000RTXL2U

Smart Online Expandable Rack / Tower UPS System - Online, double-conversion protection for mission
critical applications

Highlights

1000VA online 2U expandable rack/tower UPS

Enhanced serial communications port and SNMP/Web card slot

Maintains 120V +/-2% output during overvoltages to 138V and brownouts as low as 65V

2 load banks, 6 outlets

Fault tolerant auto-bypass

$250,000 

Ultimate Lifetime Insurance

 (USA, Puerto Rico & Canada only)

Description

Tripp Lite's Smart Online SU1000RTXL2U online, double conversion UPS protects critical server, networking and telecommunications equipment

from blackouts, voltage fluctuations and transient surges. Multi-use form factor occupies only 2 rack spaces (2U) in standard 19 inch rackmount

configuration and includes tower stands to support upright placement. Large capacity 1kVA/800 watt UPS continuously converts incoming AC to

DC, then back to perfect sine wave AC output at 120V AC (+/-2%). Removes harmonic distortion, fast electrical impulses, frequency fluctuations and

other hard-to-solve power problems not addressed by other UPS types. True sine wave output and zero transfer time offers guaranteed compatibility

with all equipment types. Includes 6 outlets arranged in two individually switchable load banks that can be independently controlled via software

interface to selectively reboot remote equipment, or shed less critical loads to extend battery runtime for more critical equipment. Battery support can

be extended indefinitely through the addition of external 2U rackmount battery packs (part# BP36V142U). Includes slot for internal SNMP/web card,

plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. Compatible with

Tripp Lite's Watchdog system service software. 

Applications

Ideal for protection of critical 120v equipment in server rooms, internetworking closets and telecommunications systems in rackmount or

tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM

workstations, concentrators, IP telephony and traditional PBX switching systems.

Package Includes

SU1000RTXL2U Online Double-Conversion UPS System 

PowerAlert Software and cabling 

Mounting hardware for 4 post rack enclosures, tower stands

Instruction manual with warranty information

Features

True online, double conversion UPS provides pure, sine wave AC output at all times

Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time

Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems

Accepts input voltages between 80 and 138 (65 to 138 at loads under 70%), regulating output to 120v +/-2%

1000VA/800 watt power capacity with 6 NEMA 5-15R outlets 

Standard internal battery set provides 18 minutes runtime at half load

Expandable runtime with multiple external battery packs (part# BP36V142U)

Innovative design makes unit adaptable for rackmount or tower applications 

Summary of Contents for SmartOnline SU1000RTXL2U

Page 1: ... or shed less critical loads to extend battery runtime for more critical equipment Battery support can be extended indefinitely through the addition of external 2U rackmount battery packs part BP36V142U Includes slot for internal SNMP web card plus DB9 enhanced serial monitoring port for unattended shutdown remote control and monitoring of UPS system and power data Compatible with Tripp Lite s Wat...

Page 2: ...watts 800 Output nominal voltage 120V AC Output voltage regulation Maintains full time sine wave output within 2 of 120V less than 5 total harmonic distortion Output frequency regulation Regulates line frequency to 50 60Hz 0 05Hz Overload protection 15A input breaker Outlet quantity type 6 NEMA 5 15R Customized load management receptacles 2 individually controllable load banks support automated lo...

Page 3: ...20V 2 during undervoltages to 80V AC Severe brownout correction At load levels less than 70 UPS maintains output of 120V 2 during undervoltages to 65V AC LEDS ALARMS SWITCHES Alarms Multi function audible alarm offers notification of UPS start backup operation low battery warning overload UPS fault and remote shutdown Switches Includes main power off on switch plus 1 switch to select battery charg...

Page 4: ...s incoming AC to DC then back to AC When commercial power is interrupted UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power Low voltage transfer to battery power Maintains continuous operation during undervoltages as low as 80V 65V at load levels under 70 Below this switchover point output is supported from battery derived AC power High voltage t...

Page 5: ...l rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products ...

Reviews: