1

INTRODUCTION

The MINUTEMAN series Uninterruptible Power Supply (UPS) has been designed to be
maintenance-free, and to provide years of excellent service.  It will provide superior power
protection for personal computers, telephone systems, and other critical equipment, against all
commercial power anomalies.  Output waveform is a Synchronized Sinewave.  Both lamp and
audible alarms indicate UPS and commercial power status at all times.  Other features include:

  External battery pack options for extended battery runtime.

 Quiet 

operation

  Excellent non-linear current capability

  LAN communications port (optional)

RECEIVING INSPECTION

SAVE THE PACKING MATERIALS!

Remove and inspect the unit for shipping damage.  If damage is found immediately notify the
carrier and your dealer.  If no damage is found save both the shipping container and the packing
foam in case of a later need to return the unit to the factory or to ship it to another location.

WARRANTY REGISTRATION

Complete the warranty registration card provided and mail it within ten days of receipt to register
your warranty.  Failure to register your warranty renders it non-valid.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

  Read this manual carefully before operating the UPS.  All instructions should be

      followed during installation and maintenance of the UPS and batteries.

  These UPS units are intended for use in a temperature-controlled, indoor area free of

conductive contaminants.

  CAUTION -- UPS units use batteries for generation of AC voltages, so output receptacles

may be electrically hot even when UPS is not connected to commercial power.  All repairs
should be performed by trained service personnel, since an electrical shock hazard exists.

  CAUTION -- Do not remove the cover: there are no user-serviceable parts inside.

  CAUTION -- To prevent electrical shock, the 3-wire plug provides earth ground for the UPS

chassis. Plug the UPS into a 3-wire grounding type commercial receptacle with grounding
conductor connected to earth ground at the service equipment.  Removal of the ground pin
from the plug or use of a 3 wire-to-2 wire adapter will defeat this safety feature and may result
in a shock hazard.  Additionally, if the plug is removed to simulate a power failure (not
recommended), do not touch the plug conductors or the chassis while the plug is removed.

Summary of Contents for MM450

Page 1: ...Minuteman Series User s Manual...

Page 2: ...its 3 7 Electrical Specifications 4 8 Computer Back Up Time vs Load 5 9 Physical Specifications 6 10 Typical Runtime vs Load Minutes 6 11 Unit Description 7 12 Installation and Test 8 13 Operation 8 1...

Page 3: ...er your warranty Failure to register your warranty renders it non valid IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Read this manual carefully before operating the UPS All instructions shoul...

Page 4: ...the skin and eyes and may be toxic CAUTION Although battery system voltages are only 24 or 48 volts battery systems can still present a risk The current capability of a battery is sufficient to burn w...

Page 5: ...be used with each Minuteman UPS without any output power derating MINUTEMAN UPS INTERNAL BATTERY SYSTEM BP TO BE USED MM450 24VDC 7 AMP HOUR BP24V10 10 AMP HOUR MM850 48VDC 7 AMP HOUR BP48V10 10 AMP H...

Page 6: ...ls Input Voltage AC Mode Function 120VAC 15VAC 220VAC 30VAC Input Frequency Deviation for Synchronization 5 Inrush Current 1 5x Rated Surge Protection 3 way meets IEEE STD 587 RFI EMI Noise Filtering...

Page 7: ...5 COMPUTER BACK UP TIME vs LOAD Internal Battery System or Standard Battery Pack COMPUTER BACK UP TIME vs LOAD UPS with Optional Battery Pack...

Page 8: ...C to 40 C 5 F to 104 F Relative Humidity 95 Max Non Condensing Maximum Altitude Without Derate 15 000 Ft Acoustic Noise Less than 60dB 3 TYPICAL RUNTIME vs LOAD MINUTES COMPUTER MM450 W MM850 W MM130...

Page 9: ...binations of locking and straight blade receptacles Optional International Plugs LEDS AC NORMAL Green when commercial voltage is in range and present provided battery circuit breaker is closed off oth...

Page 10: ...off For other models the Power Switch must be on for battery charge consequently these units may need to remain on overnight if several power outages occurred during the day When a brownout power int...

Page 11: ...will allow direct interface with many different computer operating systems This capability permits an unattended orderly shut down of the computer system when commercial power is lost for a long perio...

Page 12: ...n problems appears on the last page Do not remove the unit cover or attempt any service There are no user serviceable components inside Unauthorized service will void the warranty POLICY AND INSTRUCTI...

Page 13: ...ount or the estimated cost plus shipping and handling UPS PROBLEM CHART PROBLEM POSSIBLE CAUSE ACTION TO TAKE When UPS Power Switch is turned on UPS stays in Inverter mode Input fuse blown or input br...

Page 14: ...lowing terms and conditions Para Systems or its designated representative will at Para Systems option repair or replace any equipment so damaged provided the cost of repair or replacement of the equip...

Reviews: