XSTi Standby UPS

400VA, 600VA, 800VA Models

User & Installation Manual

www.xpcc.com

 

| © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 12/14/15)

Summary of Contents for XSTi 400VA

Page 1: ...XSTi Standby UPS 400VA 600VA 800VA Models User Installation Manual www xpcc com 2015 Xtreme Power Conversion Corporation All rights reserved Rev 12 14 15 ...

Page 2: ...ser s Manual Page 2 Uninterruptible Power Supply Table of Contents Package Contents 3 Product Introduction 3 Product Overview 3 Installation Initial Startup 4 Indicators Alarm Conditions 5 Troubleshooting 6 Specifications 7 Obtaining Service 8 ...

Page 3: ...ing you to correctly set up your system for the maximum safety and performance Included is infor mation on customer support and service if it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so that the Technical Support personnel can more effectively ass...

Page 4: ...he initial use of the UPS plug the UPS input cord into a wall outlet and turn the UPS on by depressing the Power switch on the front of the UPS For best results the batteries in the UPS should be charged for at least 8 hours before use The UPS charges its battery while it is connected to AC utility power and powered on CAUTION NEVER connect a laser printer or scanner to the UPS This may cause dama...

Page 5: ...er serviceable parts inside Refer servicing to qualified service personnel CAUTION Non isolated Battery supply Risk of electric shock battery circuit is not isolated from AC input haz ardous voltage may exist between battery terminals and ground Test before touching WARNING Unit intended for installation in a controlled environment CAUTION Do not dispose of batteries in a fire the battery may expl...

Page 6: ...verything is turned off completely and disconnected Troubleshooting Condition Visual Indicator Alarm No LED display on the front UPS panel Low battery Charge the UPS at least 8 hours Battery fault Replace the battery with the same type of battery The UPS is not turned on Press the Power Switch on the front of the UPS Alarm continuously sounds when the AC input is normal The UPS is overloaded Remov...

Page 7: ...6 ms typical Waveform Simulated Sine Wave Battery Type Qty 1 12V 4 5AH 1 12V 7AH 1 12V 9AH Runtime Up to 38 min Up to 68 min Up to 87 min Charging Time 8 hours to 90 capacity Protection Overcharge discharge short circuit and thermal Physical Dimensions W x D x H 82 5 x 228 x 207 mm 3 2 x 8 9 x 8 1 in in vertical stand position Weight 2 2 kg 4 8 lbs 2 7 kg 5 9 lbs 3 1 kg 6 8 lbs Input Cord IEC 1 5m...

Page 8: ...ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask the...