TIME

LUX

INDICATING LED

MICROPHONE

SENS

MIC

FUNCTION SWITCH

PIR SENSOR

TWILLIGHT SENSOR

Technical data can be changed without previous notice.

All right reserved.

INSTRUCTIONS

ENG |

Warranty voids if the product is mechanically damaged or connected unprofessionally.

Stated information may differ according to position and installation height.

Position marked  -  or 

 applies to minimum and position marked  

 

   or 

   

  applies to maximum.

+

Installation

Before using or installing the product, kindly read the instructions and follow safety rules. Installation should 
be provided by qualified person or company.

Thank you for choosing the item of company PANLUX s.r.o.

Technical data
Angle of detection: horizontal – 140°, vertical – 30°
Recommended installation height: 1-1,8m
Material: plastic
Switching element: TRIAC

Notice
Before using, check the product and make sure that it is not damaged, otherwise do not use it. Before any manipulation  
make sure that mains electrical supply is disconnected. In case of damage do not repair or disassemble the product. The inco-
rrect function of the product can be caused by  interruption of electromagnetic field, small temperature difference between 
moving object and surroundings, reflection (e.g. strong luminous source).

Infringement of any mentioned instruction can cause harm to health or property.

MODEL:

SL2150/B

UM_SL2150_150609

1

3

7

2

Principle of PIR sensor

PIR sensor receives infra-red waves emitted by objects in reach radius. With movement in the detection area sensor notices the change 
and initiates trigger order „Light on“ for adjusted time.

Reach setting (sensitivity) – SENS (5-9m (±1m))

Reach is to be understood as the area traced out by angle of detection and min. to max. available distance from sensor. Reach 
can be changed by knob.

Time setting (switch-off delay) – TIME (10s (±5s) to 7min (±2min))

The countdown of adjusted time begins after last detected movement. We recommend setting the function on minimum 
during functional test.

Twilight setting (response threshold) – LUX (5–2000lx)

We recommend setting the function on maximum during test.

Regulation of sound sensitivity – MIC (30-90dB)

We recommend setting the function on maximum during test.

4

6

SL2150

Function

ON – sensor is in mode of constant lighting
OFF – sensor is switched OFF
PIR – sensor is in mode PIR – it is possible to set LUX, SENS, TIME
PIR+MIC – Sensor switches on based on the currently set LUX value. It also reacts to sounds (eg. clapping). It is possible to set TIME, 
SENS, LUX and MIC.

60 m

m

N

L

80mm

56mm

52mm

35mm

3A 250VAC

IP20

TIME

10s ( ±5s)

~

7min (±2min)

LUX

5lx

~

2000lx

SENS

5~9m(±1m)

30~90dB

˚C

-20~40˚C

2x1,5mm

2

MAX

2,2A

230V

~50Hz

0,110kg

40-500W

max. 1,8m

9 m

5 m

9 m  5 m 

9m

5m

0m

0,8m