38
Subnet Mask
CIDR Pre-
Total IPs
Usable IPs
Number of Class C Net-
works
255.255.224.0 /19
8192
8190
32
255.255.192.0 /18
16,384
16,382
64
255.255.128.0 /17
32,768
32,766
128
255.255.0.0
/16
65,536
65,534
256
255.254.0.0
/15
131,072
131,070
512
255.252.0.0
/14
262,144
262,142
1024
255.248.0.0
/13
524,288
524,286
2048
255.240.0.0
/12
1,048,576
1,048,574
4096
255.224.0.0
/11
2,097,152
2,097,150
8192
255.192.0.0
/10
4,194,304
4,194,302
16,384
255.128.0.0
/9
8,388,608
8,388,606
32,768
255.0.0.0
/8
16,777,216
16,777,214 65,536
254.0.0.0
/7
33,554,432
33,554,430 131,072
252.0.0.0
/6
67,108,864
67,108,862 262,144
248.0.0.0
/5
134,217,728
134,217,726 1,048,576
240.0.0.0
/4
268,435,456
268,435,454 2,097,152
224.0.0.0
/3
536,870,912
536,870,910 4,194,304
192.0.0.0
/2
1,073,741,824 1,073,741,822 8,388,608
128.0.0.0
/1
2,147,483,648 2,147,483,646 16,777,216
0.0.0.0
/0
4,294,967,296 4,294,967,294 33,554,432
Changing the Industrial Gateway IP Address
1. Perform the activities (configuration) in Table4 (Industrial Gateway Configuration).
2. Change the laptop Host IP Address to a value in the same subnet as the new
Industrial Gateway IP address.
3. Confirm that the Industrial Gateway responds with a login dialog box
when the newly configured IP address is entered into the browser
window on the laptop.
NOTE
: For convenience, choose a unique address within the same subnet that will not
conflict with any of the new Industrial Gateway IP addresses, so the same laptop Host IP
Address can be used to test all of them.
Summary of Contents for SynapSense 1167
Page 1: ...SynapSense 2 4GHz Industrial Gateway Model 1167 Installation Use Manual ...
Page 2: ...SynapSense 2 4GHz Industrial Gateway Hardware Installation Manual 2 Release 0v6 Issue 1 ...
Page 6: ...SynapSense 2 4GHz Industrial Gateway Hardware Installation Manual 6 ...
Page 18: ...SynapSense 2 4GHz Industrial Gateway Hardware Installation Manual 18 ...
Page 29: ...29 Once the nodes are running data can be viewed in the Device Map tab ...
Page 36: ...36 ...