PES197 and PES197/E: ENGLISH
PES197 & PES197/E: PA25609A01_01
Page:
12
of
17
7-2009
EMB. MODE:
This key selects the operational mode of the embossing cycle. It is used for
tests and there are 8 choices based on the combinations of the following 3 modes:
CONTINUOUS:
Repeats the last processed plate continuously
WITHOUT PLATE:
Runs the operating cycle without controlling for the presence of a plate
PAUSE:
Executes each operation in response to the user input. The key to activate each
movement is START
ATTENTION!
If there are errors on the plate (X motor Error, & Motor Error, etc.) there are two possible
solutions:
Pressing
PAUSE/START
clears the error condition without reproducing the plate.
Pressing
FEED
activates the plate duplication procedure.
DISPLAYING THE COUNTERS OF THE PRODUCED PLATES
The statistical data of the production is available in the partial and total counters. The latter cannot be modified.
The value indicates the total number of operating cycles with and without error.
To start the counters, run the following command sequence from machine console:
SETUP
The following is displayed:
SETUP EMBOSSER
PASSWORD ?
No action required
; continue with command sequence:
←
1 ENTER
The following is displayed:
METAL MARKER PLATEXXX PLUS V.Y.YY
CNT = 0000000001 TOTAL = 0000000001
CNT: is the partial counter for the operator
TOTAL: is the total counter.
The counters are removed from the display using the same keystrokes.
To reset counters; run the following command sequence from machine console:
SETUP
The following is displayed:
SETUP EMBOSSER
PASSWORD ?
No action required
; continue with command sequence:
←
0 ENTER
The counter is Reset.