background image

Copyright

©

 2001 Panduit Corp.

PA24481A01

All Rights Reserved

11/2001

4

D.  Reverse the gage and try to insert the NO-GO side into the crimping die (Do Not use excessive force).  The

NO-GO side may partially enter the die closure but must not pass completely through.

E.  If both the GO and NO-GO conditions are met; the tool is dimensionally correct – if either condition fails,

adjust the CRIMP DIE CLOSURE as follows:

1.  Remove lock screw with small (2 mm)

 

Allen wrench [see Fig. 2].

2.  With adjustment wrench provided, turn adjustment pin one notch – each notch produces approximately

.002” of adjustment.  A clockwise turn increases the die closure and a counter-clockwise turn decreases
the die closure.

3.  Close the tool and plug gage the die closure as instructed above.  If the GO/NO-GO conditions are not

met, repeat Step (2) in one notch increments until the tool is gages to be dimensionally correct. 
Replace and tighten lock screw after final adjustment.

F.  If the above procedure fails to satisfy all GO and NO-GO conditions, contact your local 

PANDUIT

 Sales

Office.

PRODUCT INFORMATION CHART - TOOL NO. CT-460

Crimp

Die

PAN-TERM™ Terminal

Part Number

Wire Range

AWG

Wire Strip Length:

+ 1/32 / - 0 (in.)

PN 14-F, FF, LF, R

BSN 14*

18 - 14

7/32

PNF 14-F, LF, R

PTF 14-R

18 - 14

5/16

PN 14-SLF

16 - 14

7/32

PNF 14-SLF

PV 14-SLF

16 - 14

5/16

DV 14-250*

16 - 14

9/32

16 - 14

BLUE

JN 218-216*

22 - 16

7/16

PN 10-F, FF, LF, R

BSN 10*

14-10

9/32

PNF 10-F, LF, R

PTF 10-R

14-10

3/8

PN 10-SLF

12-10

9/32

PNF 10-SLF

12/10

3/8

PV 10-SLF

12-10

5/16

DV 10-250*

12-10

9/32

12-10

YELLOW

JN 418-212*

18-12

1/2

FIG. 7

* Denotes locator must be removed before terminal is crimped.

Reviews: