5 GPM tools:
To operate a 5 GPM tool, connect both tools to the ports marked 5 GPM and turn "ON" the valve corresponding to
each tool port.
10 GPM tools:
To operate a 10 GPM tool, connect it to the port marked 10 GPM and turn on both control valves.
5.2. Changing tools
•
Turn the control knobs to the "OFF" position before disconnecting hoses.
•
Once the tool has been changed, turn the valves to the "ON" position depending on flow requirements of the
tool being used.
5.3.
Cold weather operation
Hydraulic system performance is affected when the temperature drops below 50°F. Therefore, measures should be
taken to pre-warm tools and fluids before operating.
NOTE!
•
Refer to operating procedures of this manual before starting