EN 15
Resistance measurement / Continuity test / Capacity
measurement
Note Fig. 5
Attention!
Before making any measurements, make sure the circuit is
disconnected from any power source and all capacitors are properly
discharged!
•
Set the rotary switch to the position
Ω
With the function key FUNC (6.2) you switch between Resistance
measurement, Continuity test and Capacity measurement.
•
Attach the pin-plug of the black test lead to the COM-jack and the
pin-plug of the red test lead to the INPUT-jack.
•
Touch the measuring points with the probe tips.
•
For capacitors with known polarity connect the red test lead with the
anode and the black test lead with the cathode.
•
Once the reading stabilizes, read the value.
Continuity test:
If the resistance is less than about 30 Ω, you hear an
audible signal. If the circuit is open, the display shows “OL”.
Temperature measurement
•
Set the rotary switch to the position
TEMP
With the function key FUNC (6.2) you switch between °C and °F.
•
Connect the device to the K-probe. Observe the correct polarity! (Red:
INPUT, Black: COM)
•
Connect the temperature probe to the device to be tested wait a few
moments and read the value displayed.
•
If necessary, use heat conducting paste.
Contactless Voltage tester (NCV)
•
Set the rotary switch to the position
NCV
•
Keep the tip of the measuring device to a power outlet or a cable. In the
presence of dangerous voltage, a signal tone sounds and the LED indicator
lights up.
Summary of Contents for PAN 1000AD
Page 1: ...MANUAL PAN 1000AD ...
Page 2: ...F i g 1 ...
Page 3: ...F i g 2 F i g 3 ...
Page 4: ...F i g 4 F i g 5 ...
Page 6: ...Bedienungsanleitung PAN 1000 AD Digitalstromzange true RMS ...
Page 24: ...Manual PAN 1000 AD Digital clamp meter true RMS ...
Page 42: ...Manuel d instructions PAN 1000 AD Pince ampèremétrique numérique true RMS ...
Page 60: ...Istruzioni per l uso PAN 1000 AD Pinza amperometrica digitale true RMS ...
Page 78: ...Gebruiksaanwijzing PAN 1000 AD Digitale klem meter true RMS ...
Page 96: ...Bruksanvisning PAN 1000 AD Digital strömtång true RMS ...
Page 113: ...Návod na používanie PAN 1000 AD Digitálne kliešte na meranie prúdu true RMS ...
Page 131: ...Használati útmutató PAN 1000 AD Digitális lakatfogó true RMS ...
Page 149: ...Navodila za uporabo PAN 1000 AD Objemka digitalni merilnik true RMS ...
Page 167: ...Upute za uporabu PAN 1000 AD Digitalni obujmicu metar true RMS ...
Page 185: ...Instrucţiuni de folosire PAN 1000 AD Cleşte curent digital true RMS ...