OTHER TROUBLE AND ERROES
When the power switch of the welding machine is turned on, but the POWER indicator lamp does
not go on
B
When the power indicator lamp goes on, but welding cannot be done (no arc is produced)
C
Is
a
3-phase
rated
voltage being applied to
the input end of the
welding power unit ?
Is the switch of the
switch box turned on ?
When the POWER switch
[14] is turned on, does
the cooling fan start?
Is the electromagnetic
contactor turned on ?
What is a voltage at both
ends
of
the
POWER
indicator, lamp [2l] ?
The fuse(Fu1) is gone.
The
cooling
fan
is
defective.
The
printed
circuit
board is defective.
The POWER indicator lamp
is defective.
Is the switch of the
switch box turned on ?
Is the switch of the
switch box turned on ?
Is the switch of the
switch box turned on ?
The
printed
circuit
board is defective.
YES
NO
NO
NO
NO
YES
YES
DC24V
YES
Is the electromagnetic
contactor turned on ?
The electromagnetic
contactor
is
defective.
Is
the
output
cable
properly connected and
the
cable
condition
normal?
When the torch switch is
turned on, is the wire
fed ?
Is
the
output
voltage
generated?
The
printed
circuit
board is defective.
The thyristors SCR1 ~
SCR6 are damaged.
The control transformer
is defective.
Is the wire
fed
by
turning on
the inching
switch.
The
fuse(Fu2)
is gone.
The
printed
circuit board is
defective.
Is
the
wire
feeder
properly
connected?
Is
the
feed
roller of the wire
feeder
properly
set?
Is the chip not
clogged.
The
printed
circuit board
is defective.
Connect
properly and
firmly.
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
YES