DAILY INSPECTION
Cables
Block
Inspection Point
Remarks
Torch cable
Too much bent of the torch cable
Looseness at the connection to the
CC fixture
Causes a wire feed failure
Causes winking of arc due to
scooping wire feed or unstable
arc generation
Stretch out the torch cable as
straight
as
possible
when
using.
Output cable
Wear
or
damage
of
the
cable
insulator.
Exposure of the cable connection
(damaged insulation) or loosened
clamping(welding
power
unit
terminal
block,
base
material
connection, mutual cables)
To secure safety of the worker and
stable arc, carry out inspection in
an appropriate method suitable to
your work site.
Roughly and simply in daily
inspection
Elaborately
in
details
in
periodic inspection
Input cable
Whether
the
input
and
output
terminals of the input protective
device of the switch box are tight.
Whether the fuse holder is clamped
tight.
Whether the input terminal of the
welding power source is clamped
tight.
Whether the insulator of the input
cable is worn out or damaged, or the
cable is exposed
Grounding
terminal
Whether the grounding terminal for
the welding power source is firmly
connected and clamped.
Whether the grounding terminal for
the base metal is firmly connected
Be sure to inspect daily in order to
secure safety against an unexpected
leakage.