33
Notes:
• When the cursor moves to the right end "+" position, the cursor moves to the left end "-"
position. At the time, the setting value of "SC COARSE" is incremented by 1, and adjust-
ment is continuously performed.
• Holding down the right or left button for more than 1 second increases the cursor moving
speed.
• To achieve high precision adjustment, provide the video signal of the camera and program
output signal to a vector chromaticity indicator to compare the macro phases of both sig-
nals.
Adjustment of phase in VS genlock mode (VS)
The adjusting video signal of the camera and the criterial external synchronizing input signal
are connected to a 2-input oscilloscope and the phase is adjusted. Follow the procedure below
to adjust the phase.
**SYNC**
V PHASE
COARSE 1(1--16)
FINE ...|...128
- +
RET TOP END
**CAMERA SETUP** 1/2
CAMERA ID OFF
ALC/ELC ALC
SHUTTER OFF
AGC ON
SENS UP OFF
SYNC INT
WHITE BAL ATW1
MOTION DET OFF
DNR HIGH
RESOLUTION HIGH
BW MODE
"CAMERA SETUP" screen
"SYNC" screen
Step 1
Set "SYNC" to "INT" and press the setting but-
ton.
Step 2
Provide a VS signal to the external synchro-
nizing input connector on the rear side of the
camera.
→
The "SYNC" setting automatically
changes to "EXT (VS)".
Step 3
Move the cursor to "EXT (VS)" and press the
setting button.
→
The "SYNC" screen appears.
Step 4
Connect the video output signal and external
synchronizing input signal of the camera to a
2-input oscilloscope, and move the cursor to
"V PHASE".