31
6. Synchronization setting [SYNC]
This unit supports the following 5 types of synchronization methods, and one of the following is
selected.
The order of descriptions below indicates the order of priorities.
q
Multiplexed vertical drive signal (VD2)
w
Power supply synchronization (LL)
* Synchronization is performed on the basis of the power supply frequency.
e
Composite color video signal or black burst signal (VBS)
r
Monochrome composite video signal or composite synchronizing signal (VS)
t
Internal synchronization (INT) (default)
Input of a multiplexed vertical drive signal (VD2) automatically switches to the VD2 synchro-
nization even if the camera is set to other than the VD2 synchronization method.
The set item displays are shown in the chart below with accordance with a synchronization sig-
nal input.
*1: These items are switchable with use of the right or left button.
*2: When LL, VBS, or VS is selected, power supply synchronizing phase, genlock horizontal
phase, subcarrier phase, and others can be set up. (
☞
pages 32 - 34)
Notes:
• Applicable synchronization methods in areas of 60 Hz of the power supply frequency are
different from in areas of 50 Hz of the power supply frequency.
• The power supply synchronization (LL) setting is changeable only in the 50 Hz areas. The
power supply synchronization (LL) cannot be setup in the 60 Hz areas.
• When "INT" is selected, do not provide synchronization signals to the external synchroniz-
ing input connector on the rear side of the camera.
Power supply
frequency [Hz]
Synchronization signal input
VD2
VBS
VS
Menu display
50/60
50
60
b
b
X
b
X
b
b
X
X
–
b
X
–
X
b
–
X
X
–
b
X
–
X
b
–
X
X
VD2
VBS
↔
LL
*1
,
*2
VS
↔
LL
*1
,
*2
INT
↔
LL
*1
,
*2
VBS
*2
VS
*2
INT