13.4.6 Configure settings relating to HTTP alarm notification when
an alarm occurs
Click “HTTP alarm notification >>” of “Camera action on alarm” on the [Alarm] tab of the “Alarm” page.
(
Refer to page 129 for information on configuration for these settings.
13.5 Configure the VMD settings [VMD area]
Click the [VMD area] tab on the “Alarm” page. (
®
The video motion detection areas can be set on this page.
Up to 4 areas can be set. When motion is detected in the set area, it will be regarded as an alarm.
IMPORTANT
•
The alarm occurrence indication button (
®
page 9) will be displayed when motion is detected by the
VMD function.
•
The alarm occurrence indication button will be displayed when receiving an alarm input of a terminal
alarm or a command alarm.
•
Depending on the network environment, notification may be delayed even when “Real time” is selected
for “Alarm status update mode” on the [Basic] tab of the “Basic” page (
•
After configuring the VMD area, the VMD area may move out of alignment when the JPEG/H.264
“Image capture mode” setting is changed. Make sure to check the VMD area after changing the “Image
capture mode” setting.
120
Operating Instructions
13 Configure the alarm settings [Alarm]