18
E
Alarm I/O cable / 4P alarm cable (accessory)
<Ratings>
Alarm input1
/
Black & white input
/
Auto time adjustment
input, Alarm input2, Alarm input3
Input specification : No-voltage make contact input (4 V - 5 V DC, internally pulled up)
OFF
: Open or 4 V - 5 V DC
ON
: Make contact with GND (required drive current: 1 mA or more)
Alarm output, AUX output
Output specification
: Open collector output (maximum applied voltage: 20 V DC)
ON
: 4 V - 5 V DC by internal pull-up
OFF
: Output voltage 1 V DC or less (maximum drive current: 50 mA)
4P alarm cable
IMPORTANT:
Install external devices so that they do not exceed the rating of the network camera.
When using the EXT I/O terminals as the output terminals, ensure they do not cause signal
collision with external signals.
Note:
Off, input, and output of the EXT I/O terminal 2 and 3 can be switched by configuring the setting.
Refer to the Operating Instructions on the Panasonic support web site for further information
about the EXT I/O terminal 2 and 3 (ALARM IN2, 3) settings ("Off", "Alarm input", "Alarm output"
or "AUX output").
GND (Black)
ALARM IN3 (Alarm input3 / AUX output) (Gray)
ALARM IN2 (Alarm input2 / Alarm output) (Red)
ALARM IN1 (Alarm input1 / Black & white input / Auto time adjustment input)
(Green)
F
MONITOR OUT terminal (factory shipment: NTSC monitor)
Used to connect a monitor used for adjustments during installation or when performing service.
IMPORTANT:
The adjustment monitor is used for checking the adjustment of the angular field of view when
installing the camera or when servicing. It is not provided for recording/monitoring use.
Depending on the monitor, some characters (date, time, camera title, etc.) may not be dis-
played on the screen.