53
26. Add “Close (Continue)” and “Open (Continue)” to the operation
setting values of [Terminal 1], [Terminal 2], and [Terminal 3] on the
[Alarm] tab
(Operating Instructions – Configure the alarm settings [Alarm] – Configure the settings relating
to the alarm action [Alarm])
Alarm
[Terminal 1]
[S4556] [S4156] [S4576]
Determine how to use terminal 1.
•
Off:
Not used.
•
Alarm input(TRM1):
Receives alarms. When “Alarm input” is selected, a pull-down menu for “Close”
and “Open” is displayed.
–
Close:
An alarm is detected when the terminal status is changed to “Close”.
–
Open:
An alarm is detected when the terminal status is changed to “Open”.
–
Close(Continue):
An alarm is detected when the terminal status is changed to “Close”. When “Close”
is selected for the terminal status, alarm detection will be performed regularly at a fixed interval set by
“Alarm deactivation time”.
–
Open(Continue):
An alarm is detected when the terminal status is changed to “Open”. When “Open”
is selected for the terminal status, alarm detection will be performed regularly at a fixed interval set by
“Alarm deactivation time”.
•
Black & white input
[S4556] [S4576]
:
Receives the black & white switchover input. (When the input is
set to On, the black & white mode is activated.)
•
Auto time adjustment:
Receives the time adjustment input. When the signal is received and if the
clock is within 29 minutes ± the hour, the time will be adjusted to 00 minutes 00 seconds. During SD
memory card recording, the time is not changed in operations which reset the time under 5 seconds.
When “Auto time adjustment” is selected, a pull-down menu for “Close” and “Open” is displayed.
–
Close:
The time is adjusted when the terminal status is changed to “Close”.
–
Open:
The time is adjusted when the terminal status is changed to “Open”.
•
Default:
Off
[Terminal 2]
[S4556] [S4156] [S4576]
Determine how to use terminal 2.
•
Off:
Not used.
•
Alarm input(TRM2):
Receives alarms. When “Alarm input” is selected, a pull-down menu for “Close”
and “Open” is displayed.
–
Close:
An alarm is detected when the terminal status is changed to “Close”.
–
Open:
An alarm is detected when the terminal status is changed to “Open”.
–
Close(Continue):
An alarm is detected when the terminal status is changed to “Close”. When “Close”
is selected for the terminal status, alarm detection will be performed regularly at a fixed interval set by
“Alarm deactivation time”.
–
Open(Continue):
An alarm is detected when the terminal status is changed to “Open”. When “Open”
is selected for the terminal status, alarm detection will be performed regularly at a fixed interval set by
“Alarm deactivation time”.
•
Alarm output:
Alarm output will be carried out according to the settings for “Output terminal”
( Configure the settings relating to the output terminal [Alarm] [S4556] [S4156] [S4576] ).
•
Default:
Off