20
Connections
Precautions
• The following connections should be made by qualified service personnel or system installers in accordance
with all local codes.
• Turn off the power at the fuse box before starting the installation work, or it so could result in fire, electric shock,
personal injury, and material damage.
Cautions:
• FOR UL LISTED MODEL(S), ONLY CONNECT THIS TO 24 V AC CLASS 2 POWER SUPPLY.
• Be sure to connect the grounding lead to the GND terminal.
Data Port (RS485)
Alarm Input Connector
Alarm Output Connector
T(B)
T(A)
R(B)
R(A)
Red
Orange
Yellow
Green
Data
Data
(RJ-12)
Alarm In 2*5 (Red)
Alarm In 1*5 (Black)
GND*5 (Brown)
Alarm In 3*6 (Yellow)
Alarm In 4*6 (Blue)
GND*5 (Orange)
GND*6 (Green)
GND*6 (Violet)
Alarm Out 2*5 (Pink)
Alarm Out 1*5 (Grey)
GND*5 (White)
GND*5 (Light Green)
Tx
Rx
24 V AC
Brown
Blue
Green/Yellow
To the power supply
GND ( Signal grounding )*3
Coaxial Cable RG-6/U (5C-2V)*2
Data Port (RS485)
To VIDEO IN port
(CAMERA IN)
To sensor, etc.*4
To buzzer,
display device, etc.*4
To Matrix Switcher,
etc.
Video Output
Connector
Alarm Input
Connector
Alarm Output
Connector
Twisted Pair Cable*1
(BNC)
(RJ-12)
(Live)
(Neutral)
*1: For twisted pair cable, use shielded low-impedance cable with a thickness of at
least AWG#22 (0.33 mm
2
).
*2: Keep the overall length of coaxial cable under 1200 m {3937 feet} (in the case
of RG-6/U (5C-2V)).
*3: Be sure to connect the grounding lead to the GND terminal.
*4: Since a female cable is not attached, cut off the connector and connect to the
twisted pair cable of the same type.
*5: The type of twisted pair cable is AWG#28.
*6: The type of twisted pair cable is AWG#26.