12
DIP switch settings
■
Communication Parameters (DIP Switch 2)
The factory default settings are all OFF.
Switch 1:
Terminator (Internal Termination Resistance)
Set to ON in the following situations.
• When 1 camera is connected to this unit
• When 2 or more cameras are connected to this unit that works as
a termination
Switches 2 to 4:
Communication Parameters
This setting toggles between 2-line and 4-line communication. Use
these switches to select the communication protocol being used.
1
2
3
4
ON
Terminator
Communication
Parameters
1
2
3
4
ON
4-line Communication
1
2
3
4
ON
2-line Communication
1. Attaching and removing the housing base
For removing the Housing Base, refer to pages 16 to
19.
2. Set the DIP switches as the following:
Communication parameters: Set with switch 2
Unit number: Set with switch 1
Loc
k
ST
AR
T
DIP SW1
ON
1
2
3
4
5
6
7
8
DIP SW2
ON
1
2
3
4
Camera top view
DIP Switch
Important:
• Before setting up the camera for a configuration where the camera's data port (RS485) is used for camera control
(pan, tilt, etc.) by the system controller, the camera's DIP switches must be configured to specify the unit
number and communication parameters.
If DIP switch setting is not performed, the system controller control will not be possible and camera setup will