21
Camera system setting [SYSTEM SETUP]
Performs the settings relating to the camera system such as synchronization, alarm input/output terminal and privacy zone. The
following settings can be configured on the “SYSTEM SETUP” screen displayed from the top screen.
Refer to page 5 for how to call up the screen.
10. Synchronization method [SYNC]
Only internal synchronization (INT) can be used.
Multiplexed vertical drive (VD2) synchronization cannot be used.
11. Privacy zone setting [PRIVACY ZONE]
When undesired portions in the camera shooting area (on the screen) exist, those portions (privacy zone) can be set to be hidden. Up
to 8 portions can be specified for the privacy zone.
ON (1):
Grays the zone.
ON (2):
Mosaics the zone.
OFF
(default)
:
Displays the zone normally.
Follow the procedure below to set the privacy zone.
Note:
• The privacy zone function is disabled at initializing the unit, i.e. right after turning on the power.
**ZONE NUMBER 1 /8**
PUSH SET
POSITION
UPPER LEFT
RET TOP END
DEL
- +
ZONE LEVEL ..I.... 2
“SYSTEM SETUP” screen
“ZONE NUMBER” screen
ON(2)
**SYSTEM SETUP**
SYNC INT
PRIVACY ZONE
STABILIZER OFF
EL-ZOOM OFF
UPSIDE-DOWN OFF
- +
LDC I...... 0
RET TOP END
Step 1
Move the cursor to “PRIVACY ZONE”, select “ON (1)” or “ON (2)”, and press the [SET] button.
→
The “ZONE NUMBER” screen appears.
Step 2
Move the cursor to the number at the right of the title and select the zone number using the [RIGHT] or [LEFT] button.
Step 3
Move the cursor to “POSITION” and press the [SET] button.
Step 4
Press the [UP], [DOWN], [RIGHT], and [LEFT] buttons to determine the left upper position of the zone to be set and press the [SET]
button.
“SYSTEM SETUP” screen
**SYSTEM SETUP**
SYNC INT
PRIVACY ZONE OFF
STABILIZER OFF
EL-ZOOM OFF
UPSIDE-DOWN OFF
- +
LDC I...... 0
RET TOP END