70
DP-2330/3030
DEC 2004
Ver.2.0
DP-2310/3010
503
XMT/
RCV(V.34)
B, C, D CS of modem is not able to turn
ON during training.
FXB PCB defective.
Line disconnected.
504
RCV/V.34
(Polling)
B
Polling is rejected from the remote
station.
No polling original set.
505
XMT/V.34
(Polling)
B
Polling XMT is rejected.
No polling original set.
540
XMT ECM
B
No response after transmitting 3rd
CTC or DCN received.
Incompatible interface.
541
XMT ECM
D
No response after transmitting 3rd
EOR or received DCN.
Faulty line.
MJR PCB abnormal.
542
XMT ECM
D
No response to the 3rd RR
transmitted or received DCN.
Remote unit abnormal.
543
XMT ECM
D
T5 timer (60 sec.) elapsed without
MCF.
Remote unit abnormal.
544
XMT ECM
D
Stopped Transmission after EOR
Transmission.
Faulty line.
MJR PCB abnormal.
550
RCV ECM
C
Timer between frames in phase C
has elapsed.
Defective remote station.
554
RCV ECM
D
Transmitted ERR after receiving
EOR.
Faulty line.
555
RCV ECM
D
Transmitted PIN after receiving
EOR.
Faulty line and Operator Call requested
by RX side.
570
RCV
B
Password or machine code did not
match during remote diagnostic
communication.
571
XMT
B
Remote unit did not have the
remote diagnostic function.
580
XMT
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
581
XMT
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
582
XMT
B
Sub-address SEP (for Polling)
transmission to a unit that has their
DIS bit 47 (NSF bit 130) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
601
XMT
ADF Door was opened during ADF
transmission.
623
XMT
A
No original was in the ADF. (Built-
in dialer engaged)
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the ADF.
630 XMT or RCV
(Polling)
B
Redial count over.
No dial tone detected. Sensor dial tone
is not detected. (Country dependent)
Busy tone is detected. (Country
dependent) T1 timer (35±5 sec) elapsed
without a signal from the receiver.
631
XMT
A
"STOP" key was pressed during
Auto Dialing.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Possible Cause(s)
Summary of Contents for Workio DP-3010