37
DP-2330/3030
DEC 2004
Ver. 2.0
DP-2310/3010
2.6.
Lubrication Point List
This information is used for routine Preventive Maintenance (PM) calls to ensure the highest degree of
reliability. Inspect the following areas and lubricate as required. The inspection interval is usually 120K
copies or more, however the interval may be reduced due to environmental conditions.
Mechanical Parts
Ref.
No.
Grease
Lubrication Point
Fuser Unit
Pressure Spring
1029
EM-50L
Shoulder Screw
1033
Idle Roller
1049
EM-50L
Pinch Shaft
1068
Dual-Path Exit Guide
Top Duplex Guide
1406
EM-50L
Pinch Spring
1411
Pinch Roller
1518