36
●
PS·Data Mode Connection
To apply the PS·Data mode, connect the system controllers
as follows.
1. Connect the system controllers to the DATA 1 port of
Video Output Board 1.
Notes:
• In the factory default, the DATA 1 port is set for the ter-
minal mode connection. To apply the PS·Data mode
connection, perform the DATA port settings in DATA
PORT of SETUP MENU (refer to p. 53) or "System" –
"DATA Port" of WJ-SX650 Series Administrator Console.
• Both of terminal mode and PS·Data system controllers
cannot be connected to the same DATA port.
• DATA 1 port of Video Output Board 2 cannot be set for
the PS·Data connection.
• 1 200 m {3 937 ft} is the total length limit of cables
(between this unit and the system controller at the chain
end).
• Up to 4 system controllers can be connected in the
daisy chain. For system controllers in the daisy chain
connection, operator registration is not available. (The
same operator setting is applied for all the system con-
trollers in the PS·Data daisy chain.)
2. If using only one system controller, set the MODE
Switch #2 of DATA port connected to the system con-
troller to ON. If using two or more system controllers in
daisy chain connections, set the MODE Switch #2 of
DATA port of the chain-end unit to ON.
3. Set the system controllers to the PS·Data mode. (Refer
to the operating instructions of system controllers.)
4. Set the line termination of system controllers with the
MODE switches. (Refer to the operating instructions of
system controllers.) In the daisy chain connection, set
the line termination of chain end system controller to
ON. (Switch #5: ON)
5. In the daisy chain connection, set the CONTROLLER
NO. switches of system controllers to 1 to 4. The switch
setting must be different from each other. (Refer to the
operating instructions of system controller for details on
the CONTROLLER NO. switch setting.)
Note:
When using system controllers in the PS·Data
mode, camera numbers that can be selected differ
depending on system controller models.
Example:
WV-CU950/650:
1 to 999
WV-CU360C/CJ:
1 to 199
Select the system controller models that are applic-
able for your system composition. When using 200
or more cameras in the PS·Data mode, apply WV-
CU950/650.
OUT X-2
1
2
3
4
5
6
7
8
MONITOR OUT
9
10
11
12
13
14
15
16
EXTENSION 1
TERM.
OFF
ON
OUT
IN
OUT X-3
MODE
MODE
DATA
1
2
MODE
MODE
DATA
3
4
TERM.OFF
ON
MODE
TERM.ON
MODE
DATA 4
HDR4/TMNL8
HDR2/TMNL4
DATA 3
HDR3/TMNL7
HDR1/TMNL3
DATA 2
TMNL6
TMNL2
DATA 1
TMNL5
TMNL1/PS DATA
Video Output Board 2
Video Output Board 1
OUT X-1
ALARM OUT 2
ALARM OUT 1
SERIAL
VS OUT
VS IN
VS OUT
(THRU)
Video Output Board 1 Only
1
3
2
4
6
5
7
9
8
0
SYSTEM CONTROLLER
1
3
2
4
6
5
7
9
8
0
SYSTEM CONTROLLER
1
3
2
4
6
5
7
9
8
0
SYSTEM CONTROLLER
1
3
2
4
6
5
7
9
8
0
SYSTEM CONTROLLER
A
B
1
3
2
4
6
5
7
9
8
0
SYSTEM CONTROLLER
DATA1
DATA2
ON
1 2
CONTROLLER NO.: 4
Line termination: ON
CONTROLLER NO.: 3
Line termination: OFF
CONTROLLER NO.: 2
Line termination: OFF
CONTROLLER NO.: 1
Line termination: OFF
CONTROLLER NO.: 1
Line termination: ON
Daisy chain connection
Line termination:
ON (#2: ON)
Video output
rear boards
Matrix Switcher WJ-SX
650
650
Matrix Switcher WJ-SX
650
650
Matrix Switcher WJ-SX
650
650
A
B
1
3
2
4
6
5
7
9
8
0
SYSTEM CONTROLLER
OPERATE
OPERATE LED WILL BLINK
IF COOLING FAN MALFUNCTIONS
OPERATE
OPERATE LED WILL BLINK
IF COOLING FAN MALFUNCTIONS
Cable Kit
WV-CA48/10K
CONTROLLER NO.: 1
Unit Address: 1
Line termination OFF
Unit Address: 2
Line termination OFF
Unit Address: 3
Line termination ON
OPERATE
OPERATE LED WILL BLINK
IF COOLING FAN MALFUNCTIONS