-45-
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
[Spot]
[Quad Spot]
[Quad Sequence]
ALARM
2. Alarm Indication Mode
• The camera pictures selected before alarm was
activated remain on the monitor screen.
• If the alarmed channels are displayed, the camera
title and alarm display blink alternately on the moni-
tor screen.
Note:
If the alarm channel is in the Still mode, it
returns to normal viewing.
●
Spot Output
1. Alarm Spot Mode
• The alarmed camera picture is displayed in Single
Spot mode on the spot monitor. When another
alarm is received, the display switches to showing
the most recent alarmed camera picture in Single
Spot mode.
• The camera title and alarm display are alternately
flashed on the monitor.
2. Alarm Ignore Mode
• The camera pictures selected before alarm was
activated remain on the monitor screen.
• If the alarmed channels are displayed, the camera
title and alarm display blink alternately on the moni-
tor screen.
●
Record Output
• Alarms are recorded in the mode specified for the
ALM REC MODE parameter on the ALARM SETUP
menu.
• Alarmed channels are recorded with more fields
than in normal recording if ON is specified for the
DYNAMIC REC parameter in the ALARM SETUP
menu.
●
Multiscreen Output
1. Alarm Link Mode
• The picture of the alarmed camera is displayed in
Single Spot mode on the multiscreen monitor. The
LED on the corresponding CAMERA button blinks.
• When multiple alarms are activated, the pictures of
the alarmed cameras are displayed on a quad
screen in the order of upper left to lower right seg-
ment. From the fifth alarm on, the pictures are over-
written in the order of upper left to lower right seg-
ment, and then displayed in sequence with the pre-
vious quad pictures.
• The Dwell Time for each step can be programmed
on the ALARM SETUP menu.