Warning mail
The following mail will be sent to notify of a trouble occurrence to a registered address when the trouble occurs.
HD600 (192.168.0.250) STATUS REPORT
DATE: 2009-1-1 12:00:00
STATUS: The description of the trouble will be displayed. (Example: MAIN THERMAL
ERROR)
Indication
Description
DATE
Time and date when the trouble occurred will be displayed.
STATUS
The description of the trouble will be displayed.
Thermal error:
Alteration detection:
HDD S.M.A.R.T. warning:
HDD remaining capacity
warning* :
HDD hour meter warning:
Power outage detection:
Auto remove of link:
Fan error:
Copy media error:
Other errors:
HDD error:
RAID recovery failure:
MAIN THERMAL ERROR
ALTERED XX CH (XX indicates camera channel number.)
MAIN-Y SMART WARNING
Y indicates disk number
<except FULL>
NORMAL-HDD CAPACITY REMAINS**%
EVENT-HDD CAPACITY REMAINS**%
** indicates the set value (%) - 1
<FULL>
EVENT-HDD FULL
HOUR METER WARNING
POWER LOSS
MAIN-Y
LOGICALLY REMOVED
Y indicates disk number
1DOWN
FAN ERROR
MEDIUM ERROR
UNDEFINED ERROR
HDD-ERROR
MAIN RAID 5 RECOVERY FAILURE
x indicates unit number
*HDD remaining capacity warning
A warning mail with the <except FULL> content will be sent when the remaining disk capacity becomes less
than the set value for "HDD capacity warning" in the "Maintenance" menu. After a warning mail is sent, a warn-
ing mail with the <except FULL> content will be sent each time 1% of the remaining disk capacity is reduced,
and a warning mail with the <FULL> content will be sent when there is no remaining disk capacity.