Outdoor Unit
Performance Test Condition
EUROVENT
Heating Capacity
kW
9.00
BTU/h
30700
kJ/h
32400
COP
W/W
4.10
BTU/hW
14.0
Noise Level
dB (A)
53
Power Level dB
67
Air Flow
m
3
/min (ft
3
/min)
55.1 (1945)
Refrigeration Control Device
Expansion Valve
Refrigeration Oil
cm
3
FV50S (900)
Refrigerant (R410A)
kg (oz)
1.45 (51.2)
Dimension
Height
mm (inch)
795 (31-5/16)
Width
mm (inch)
900 (35-7/16)
Depth
mm (inch)
320 (12-19/32)
Net Weight
kg (lbs)
66 (146)
Pipe Diameter
Liquid
mm (inch)
6.35 (1/4)
Gas
mm (inch)
15.88 (5/8)
Standard Length
m (ft)
7 (23.0)
Pipe Length Range
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height Difference
m (ft)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
Refrigeration Charge Less
m (ft)
10 (32.8)
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Rated Output
kW
1.70
Fan
Type
Propeller Fan
Material
PP
Motor Type
Transistor (8-poles)
Input Power
W
—
Output Power
W
60
Fan Speed
rpm
640
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Row
×
Stage
×
FPI
2
×
30
×
17
Size (W
×
H
×
L)
mm
38.1
×
762
×
873.8 : 903.8
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V 230
Hz
50
Input Power
kW
2.20
Maximum Input Power
kW
4.37
Starting Current
A
10.10
Running Current
A
10.10
Maximum Current
A
20.0
Power Factor
%
95
Power factor means total figure of compressor and outdoor fan motor.
Power Cord
Number of core
-
Length
m (ft)
-
Thermostat
Electronic Control
Protection Device
Electronic Control
Summary of Contents for WHSD24BE51
Page 10: ...10 4 Location of Controls and Components 4 1 Indoor Unit 4 1 1 Location of Control ...
Page 11: ...11 ...
Page 12: ...12 4 1 2 Main Components 4 2 Outdoor Unit ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit ...
Page 14: ...14 5 2 Outdoor Unit ...
Page 16: ...16 7 Block Diagram ...
Page 17: ...17 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 18: ...18 8 2 Outdoor Unit ...
Page 19: ...19 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 20: ...20 9 2 Outdoor Unit ...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 22: ...22 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Page 23: ...23 10 2 2 Capacitor Printed Circuit Board 10 2 3 Noise Filter Printed Circuit Board ...
Page 71: ...71 17 3 To Remove Pressure Gauge 17 4 To Remove Control Panel ...
Page 72: ...72 17 5 To Remove Electronic Controller Board and Transformer 17 6 To Remove RCCB ...
Page 74: ...74 When reinstall the water pipe use grease or water at the joining ...
Page 79: ...79 18 3 Hydraulic Pump Performance ...
Page 82: ...82 19 2 WH UD24BE5 1 WH UD30BE5 1 ...
Page 83: ...83 ...