1. Safety Precautions 

  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 

  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating and main 

circuit for the model installed. 

  The caution items stated here must be followed because these important contents are related to safety. The 

meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction 
will cause harm or damage, and the seriousness is classified by the following indications. 

 

 

This indication shows the possibility of causing death or serious injury. 

 

This indication shows the possibility of causing injury or damage to properties. 

 

  The items to be followed are classified by the symbols: 

 

 

  Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, 

care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for 
future reference. 

 

 

1.   Do not modify the machine, part or material during repairing service. 

2.   If wiring unit is supplied as repairing part, do not repair or connect the wire even partial wire break. Exchange the whole wiring unit. 

3.   Do not wrench the fasten terminal. Pull it out or insert it straightly. 

4.   Do not install outdoor unit near handrail of veranda. When installing outdoor unit at veranda of high rise building, child may climb up to 
      outdoor unit and cross over the handrail and causing accident. 

5.   Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other 
      electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire. 

6.   Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen. 

7.   Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 

8.   Do not sit or step on the unit, you may fall down accidentally. 

9.   Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing. 

10. Do not use pipe wrench to install refrigerant piping. It might deform the piping and cause the unit to malfunction. 

11. Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or fire. 

12. Do not modify the wiring of indoor/outdoor unit for installation of other components (i.e. heater, etc). Overloaded wiring or wire 
      connection points may cause electrical shock or fire. 

13. Do not add or replace refrigerant other than specified type. It may cause product damage, burst and injury etc. 

14. For electrical work, follow local wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be 
      used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 

15. For water circuit installation work, follow to relevant European and national regulations (including EN61770) and local plumbing and building 
      regulation codes. 

16. Engage dealer or specialist for installation or servicing. If the installation or servicing done by the user is defective, it will cause water leakage,
      electrical shock or fire. 
17. This is a R407C model, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause 
      abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R407C refrigerant. 
      Thickness or copper pipes used with R407C must be 0.8 mm or more. Never use copper pipes thinner than 0.8 mm. 
      It is desirable that the amount of residual oil is less than 40 mg/10 m. 
18. When install or relocate Air to Water Heatpump indoor/outdoor unit, do not let any substance other than the specified refrigerant, eg. air etc 
      mix into refrigerant cycle (piping). Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc. 

 

 

This symbol denotes item that is PROHIBITED from doing. 

Summary of Contents for WH-SHF09F3E8 Series

Page 1: ... This service information is designed for experienced repair technicians only and is not designed for use by the general public It does not contain warnings or cautions to advise non technical individuals of potential dangers in attempting to service a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to service or repai...

Page 2: ...rotating fan may cause injury 8 Do not sit or step on the unit you may fall down accidentally 9 Keep plastic bag packaging material away from small children it may cling to nose and mouth and prevent breathing 10 Do not use pipe wrench to install refrigerant piping It might deform the piping and cause the unit to malfunction 11 Do not purchase unauthorized electrical parts for installation service...

Page 3: ...rical equipment at wooden building of metal lath or wire lath in accordance with electrical facility standard no electrical contact between equipment and building is allowed Insulator must be installed in between 33 Work done to the indoor outdoor unit after remove the front plate cover that secured by screws must be carried out under the supervision of authorized dealer and licensed installation ...

Page 4: ... 7 23 0 Pipe Length Range m ft 3 9 8 30 98 4 I D O D Height Difference m ft 20 65 6 Additional Gas Amount g m oz ft 70 0 8 Refrigeration Charge Less m ft 10 32 8 Type Hermetic Motor Rotary Motor Type Brushless 4 poles Compressor Rated Output kW 3 40 Type Propeller Fan Material PP Motor Type Induction 8 poles Input Power W Output Power W 60 Fan Fan Speed rpm 510 Top Fan 550 Bottom Fan Fin material ...

Page 5: ...nch 28 1 3 32 Water Pipe Diameter Outlet mm inch 28 1 3 32 Water Drain Hose Inner Diameter mm inch 15 00 19 32 Motor Type DC Motor No of Speed 7 Software Selection Pump Input Power W 60 Type Brazed Plate No of Plates 80 Size H W L mm 130 93 325 Hot Water Coil Water Flow Rate l min m 3 h 34 4 2 1 Pressure Relief Valve Water Circuit kPa Open 300 Close 265 and below Flow Switch Magnetic Lead Switch P...

Page 6: ... Protection Feature Random auto restart after power failure for safety restart operation Gas leakage protection Prevent compressor reverse cycle Inner protector to protect compressor Serviceability Feature Breakdown Self Diagnosis function System Status Check Buttons for servicing purpose System Pumpdown Button for servicing purpose Front maintenance design for outdoor unit Operation Condition Ind...

Page 7: ... 155 97 157 171 57 Relative position between the indoor unit and the installation plate Front View Top View Front View Side View Bottom View 502 116 496 353 360 17 41 4 2 6 74 9 110 5 6 4 0 140 7 306 4 140 7 63 63 213 5 213 5 490 52 5 Installation Plate 6 6 Indoor unit external dimensions line 3 1 5 H O L E Unit mm ...

Page 8: ...20 5 2 Outdoor Unit Unit mm Top View Front View Side View 900 400 320 355 900 318 5 253 210 165 243 1340 615 320 40 40 20 110 356 5 Side view Back view 30 ...

Page 9: ... Refrigerant Cycle Water Cycle Heat Exchanger Heat Exchanger Strainer Strainer 4 Way Valve Gas Side 3 Way Valve Liquid Side 2 Way Valve Accumulator Pressure Switch High Pressure Sensor Compressor Discharge Temp Sensor Compressor Tank Temp Sensor Compressor Water Pressure Gauge Capillary Tube Strainer Strainer Subcooler Expansion Valve Bypass Muffler Expansion Valve Air Purge Valve Piping size Mode...

Page 10: ... 3 WAY VALVE N SIGNAL DETECTION CIRCUIT NOISE FILTER CIRCUIT SW201 GROUNDING LA1 LA2 LA3 N SURGE PROTECTION CIRCUIT RCCB BL BL BL GR 400V 25A l n 30mA GROUNDING TERMINAL BOARD BACKUP HEATER POWER SUPPLY 2 3 phase AC400V 50Hz LB1 LB2 LB3 N OLP 80 3 C BR 2 BR OLP 80 3 C O O OLP 80 3 C 3 3 2 1 1 2 3 4 1 2 3 4 1 W W W R BL R O Y BR B W A FUSE2 20A 500V SIGNAL DETECTION CIRCUIT B B OLP 80 3 C 1 2 CN FL...

Page 11: ... 1 HIGH PRESSURE SWITCH R R ELECTRO MAGNETIC COIL BYPASS EXPANSION VALVE 1 1 ELECTRO MAGNETIC COIL MAIN EXPANSION VALVE DISCHARGE TEMP SENSOR THERMISTOR 6 2 6 W 1 1 2 CN TH2 BLUE CN TH3 BLACK CN EV1 WHITE CN EV2 YELLOW CN FM1 WHITE CN FM2 RED CN PSW1 BLUE 1 1 2 4 CN TH1 WHITE 1 4 LOWER FAN MOTOR UPPER FAN MOTOR 3 ELECTRONIC CONTROLLER MAIN ELECTRONIC CONTROLLER NF ELECTRO MAGNETIC COIL 4 WAY VALVE...

Page 12: ...will operate ON and OFF for 10 minutes to purge the air in the hydraulic system Press again the FORCE button to exit AIR PURGE function PUMP SPEED ADJUST MODE will stop operation P Q 110 100 1 2 3 4 5 6 7 90 80 70 60 50 40 30 20 10 0 0 10 13 20 30 40 50 60 EXTERNAL STATIC PRESSURE kPa NOT APPLICABLE RANGE NOT APPLICABLE RANGE WATER FLOW RATE I min 14 6 Expansion Vessel Pre Pressure Checking x Expa...

Page 13: ... C DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Outdoor Temperature C Outdoor Temperature C Input Power kW Outdoor Temperature C Capacity kW 1 000 2 000 3 000 4 000 5 000 6 000 15 11 7 3 1 5 9 13 17 21 25 10 000 11 000 12 000 13 000 14 000 15 000 15 11 7 3 1 5 9 13 17 21 25 ...

Page 14: ...C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Piping Length m Piping Length m Input Power kW Piping Length m Capacity kW 1 500 2 000 2 500 3 000 3 500 4 000 3 6 9 12 15 18 21 24 27 30 8 000 9 000 10 000 11 000 12 000 13 000 3 6 9 12 15 18 21 24 27 30 ...

Page 15: ...00 5460 2 9000 4350 9000 4760 7 9000 3460 9000 3960 16 8200 2770 8200 3180 25 9800 2890 9600 3310 18 2 2 WH UH12FE8 Water Out C 30 35 40 45 50 55 Outdoor Air C Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W 15 12000 5160 12000 5530 11000 5510 10600 5530 10300 5630 9700 5760 7 12000 4430 12000 476...

Page 16: ... Table WH SHF09 WH SHF12 Outdoor Air C Capacity W Input Power W Capacity W Input Power W 3 9000 1950 12000 2710 7 9000 1940 12000 2690 10 8000 1840 10300 2510 20 7400 1840 9500 2510 30 7000 1840 9000 2510 18 4 Usage Limitation ...

Reviews: