8
Item
Unit
Running Current
A
4.2
5.6
Maximum Current For Heat Pump System
A
10.8
Power Factor
%
94
95
Power factor means total figure of compressor and outdoor fan motor.
Number of core
-
Power Cord
Length m
(ft)
-
Thermostat
Electronic
Control
Protection Device
Electronic Control
Item
Unit
Indoor Unit
Performance Test Condition
EN14511
Outdoor Ambient
°C
-20 ~ 35
Operation Range
Water Outlet
°C
25 ~ 65
Internal Pressure Differential
kPa
39.8
dB (A)
33
Noise Level
Power Level dB
46
Height
mm (inch)
892 (35-1/8)
Width
mm (inch)
502 (19-3/4)
Dimension
Depth
mm (inch)
353 (13-29/32)
Net Weight
kg (lbs)
48 (106)
Liquid
mm (inch)
9.52 (3/8)
Refrigerant Pipe Diameter
Gas
mm (inch)
15.88 (5/8)
Inlet
mm (inch)
28 (1-3/32)
Water Pipe Diameter
Outlet
mm (inch)
28 (1-3/32)
Water Drain Hose Inner Diameter
mm (inch)
15.00 (19/32)
Motor Type
DC Motor
No. of Speed
7 (Software Selection)
Pump
Input Power
W
60
Type
Brazed
Plate
No. of Plates
80
Size (H × W × L)
mm
130 × 93 × 325
Hot Water Coil
Water Flow Rate
l/min (m
3
/h) 34.4
(2.1)
Pressure Relief Valve Water Circuit
kPa
Open: 300, Close: 265 and below
Flow Switch
Magnetic Lead Switch
Protection Device
A
Residual Current Circuit Breaker / Earth Leakage Circuit Breaker (25)
Volume I
10
Expansion Vessel
MWP bar
3
Capacity of Integrated Electric Heater
kW
9.00
Note:
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C.
Specification are subjected to change without prior notice for further improvement.