97
16.5.17. Outdoor Fan Motor (DC Motor) Mechanism Locked (F15)
Malfunction Decision Conditions:
The rotation speed detected by the Hall IC of the fan motor during fan motor operation is used to determine abnormal fan motor
(feedback of rotation > 2550rpm or < 50rpm).
Malfunction Caused:
1. Operation stop due to short circuit inside the fan motor winding.
2. Operation stop due to breaking of wire inside the fan motor.
3. Operation stop due to breaking of fan motor lead wires.
4. Operation stop due to fan motor Hall IC malfunction.
5. Operation error due to faulty outdoor unit PCB.
Abnormality Judgment:
Continue 2 times in 30 minutes.
Summary of Contents for WH-MDC09C3E5
Page 14: ...14 4 Location of Controls and Components 4 1 Monobloc Unit ...
Page 17: ...17 ...
Page 18: ...18 ...
Page 19: ...19 4 1 2 2 Weekly Timer Setting ...
Page 20: ...20 4 1 2 3 Setting Up The Special Functions ...
Page 21: ...21 5 Dimensions 5 1 Monobloc Unit ...
Page 22: ...22 6 Refrigeration And Water Cycle Diagram ...
Page 23: ...23 ...
Page 24: ...24 7 Block Diagram 7 1 WH MDC09C3E5 ...
Page 25: ...25 7 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Page 26: ...26 8 Wiring Connection Diagram 8 1 WH MDC09C3E5 ...
Page 27: ...27 ...
Page 28: ...28 8 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Page 29: ...29 ...
Page 30: ...30 9 Electronic Circuit Diagram 9 1 WH MDC09C3E5 ...
Page 31: ...31 ...
Page 32: ...32 9 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Page 33: ...33 ...
Page 34: ...34 10 Printed Circuit Board 10 1 Water System 10 1 1 Main Printed Circuit Board ...
Page 35: ...35 10 1 2 Solar Printed Circuit Board Optional ...
Page 36: ...36 10 2 Refrigerant System 10 2 1 Main Printed Circuit Board ...
Page 37: ...37 10 2 2 Capacitor Printed Circuit Board 10 2 3 Noise Filter Printed Circuit Board ...
Page 38: ...38 11 Installation Instruction Monobloc Unit Dimension Diagram ...
Page 39: ...39 Main Components ...
Page 52: ...52 Solar Priority is Set Solar Priority is Not Set ...
Page 55: ...55 Heat Tank Heating No Priority Solar Priority Set ...
Page 56: ...56 Heat Tank Heating No Priority Solar Priority Not Set ...
Page 66: ...66 Solar Priority Not Set Heat Tank Mode Heating Priority Set ...
Page 67: ...67 Tank Mode Solar Priority Set Solar Priority Not Set ...
Page 115: ...115 17 3 To Remove The Cabinet Rear Plate 17 4 To Remove Pressure Gauge 17 5 To Remove RCCB ...
Page 130: ...130 ...
Page 134: ...134 19 2 WH MDC09C3E5 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 Water System ...