6
To adjust initial settings
Dealer
Select menus and determine settings according to the system available in the
household. It is recommended that all alterations of settings are done by an
authorised dealer or specialist.
• After initial installation, you may manually adjust the settings.
The initial setting remains active until the user changes it.
• The remote control can be used for multiple installations.
• Ensure the operation LED is OFF before setting.
• The system may not work properly if set wrongly. Please consult
an authorised dealer.
1
Press and
simultaneously and hold for
5 seconds until the display shows SETTING STATUS.
2
Press or to select the menu.
3
Press
to enter the menu.
4
Press or to select YES/NO, or other options.
YES:
to enable the menu
NO:
to disable the menu
5
Press to confirm.
Remote Control
Display
Operation LED
Menu (1 ~ 20)
Setting
Display
1
Room Thermostat Connection
To select whether or not to connect to the optional room thermostat.
YES
NO
2
Backup Heater Selection
To reduce the heater power if unnecessary.
*Options of kW vary depending on the model.
*3 kW / 6 kW /
9 kW
3
Water System Freeze Prevention
To activate or deactivate the water freeze prevention when the system is OFF.
YES
NO
4
Tank Connection
To select whether or not to connect to the optional water tank unit.
Note: If NO is selected, menus 5 to 15 are skipped.
YES
NO
5
Solar Priority
To select the use of solar panel for heating up the water tank.
YES
NO
6
*
1,
*
2
Cooling Priority
To choose the room cooling as priority during COOL + TANK mode.
Note: If YES is selected, menus 8 and 9 are skipped for COOL + TANK mode.
YES
NO
7
Heating Priority
To select the room heating as priority during HEAT + TANK mode.
Note: If YES is selected, menus 8 and 9 are skipped for HEAT + TANK mode.
YES
NO
8
*
1,
*
2
Cooling/Heating Operation Interval
To set the interval for COOL or HEAT mode during COOL + TANK or HEAT +
TANK mode.
Note: If YES is selected in menus 6 and 7, this menu is skipped.
0.5 hours ~
10 hours
9
*
1
Tank Heat-up Interval
To set the interval for the water tank during COOL + TANK or HEAT + TANK
mode.
Note: If YES is selected in menus 6 and 7, this menu is skipped.
5 minutes ~
1 hour 35 minutes